2711-T9C10L1 Product Details

The Allen-Bradley 2711-T9C10L1 Operator Terminal lets the user interface with a machine. This terminal belongs to the Allen-Bradley PanelView 900 series and it has a 9-inch color display. The nominal power that is needed for this terminal is 24 Volts DC. There is a 1008-KB internal memory in this unit. Users can connect the 2711-T9C10L1 to other machines with the Panelbuilder 32 software, with DeviceNet, or with the RS-232 printer communication port and a 2711-NC13 communication cable. The user can control the interface terminal by using the touchscreen to enter data. The internal backlight of this unit is replaceable. The replacement part number for the backlight is 2711-NL2. The 2711-T9C10L1 is a DeviceNet terminal that connects to and communicates with other machines at the device level. To be more specific, it communicates and connects to other machines on a DeviceNet link at a rate of 125k, 250k or 500k baud. The 2711-T9C10L1 can connect to SLC, PLC, and ControlLogix controllers on the link. A DeviceNet scanner module is used by the link and direct access to the stored data minimizes the need for ladder logic. Users can download or upload application files using the PanelBuilder32 software over the DeviceNet network, through the onboard RS-232 printer port, or with a PC memory card. There is enhanced troubleshooting on the DeviceNet network. Terminals communicate with a range of devices on the network. 

The Allen-Bradley 2711-T9C10L1 is an interface terminal in the PanelView 900 series. This HMI has a 9-inch color display, 24 Volts of DC power, and 1008 KB of internal memory. It also has Panelbuilder 32 software, DeviceNet, and an RS-232 Printer communication port with 2711-NC13 communication cables. The 2711-T9C10L1’s touchscreen can input data. The internal backlight of this unit is replaceable. The shipping dimensions of this unit are 16 x 14 x 8 inches and the weight is 7.9 pounds. The 2711-T9C10L1 terminals can communicate at the device level on a DeviceNet link using I/O, server explicit, client explicit, or listen-only messaging. They can connect to SLC, PLC, and ControlLogix devices. The DeviceNet network supports cyclic, peer-to-peer messaging, polled, and change-of-state for efficient communication. The DeviceNet has enhanced troubleshooting. Terminals communicate with a range of devices on the network. The interface of 2711-T9C10L1 is certified DeviceNet compliant, guaranteeing compatibility with other compliant devices.

Technical specifications:
Manufacturer:Rockwell Automation
Part Number/Catalog No.:2711-T9C10L1
Product Line:Panelview 900
Display Size:9 in.
Display Color:Color
Input Type:Touchscreen
Communication:DeviceNet and RS-232 Printer
Input Power:24 VDC
Software:Panelbuilder 32
Memory:1008K bytes
Backlight:2711-NL2
Communication Cable:2711-NC13
Shipping Weight:8 lbs.
Shipping Dimensions:16 x 14 x 8 in
Series :A, B, C, D, E, F
Firmware:1.00-4.48
FAQ

The PanelView Standard operator terminals have multiple models: the 300, 550, 600, 900, 1000, and 1400. The PanelViews are Top Rated Electronic Operator Terminals engineered to suit your needs. The Panelviews have high performance flat panel designs or 14-inch CRTs. These electronic human interfaces feature excellent graphics capabilities. They have high performance functionality in color, gray scale and monochrome displays. The PanelView Standard family offers you rugged electronic human interface solutions. There are many different sizes and configurations to meet your specific requirements. This PanelView Standard class of operator interfaces offers you Flexible Communications and Controller Connectivity. There are several communication options such as Allen-Bradley’s MicroLogix, SLC 500, PLC, and ControlLogix, and other PLC manufacturers. HMI is the acronym for Human Machine Interface, which is an interface between the user and the machine. It provides a graphics-based visualization of an industrial control and monitoring system. It also provides a visual representation of a control system and provides real time data acquisition. A HMI can increase productivity by having a centralized control center that is user-friendly.

Type Lead Time Price Action
Repair Service 3-5 days AskGet Quote

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures

Common misspellings: 2711-T9C10L1X
27l1-T9C10L1
271l-T9C10L1
2711-T9Cl0L1
2711-T9C1oL1
2711-T9C1011
2711-T9C10Ll
2711-T9C10L1X
2711P-T9C10L1
2711T9C10L1