    Technical Specifications for 2711-T9C9L1

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-T9C9L1
Product LinePanelview 900
Display Size9 in.
Display ColorColor
Input TypeTouchscreen
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 VDC
SoftwarePanelbuilder 32
Memory1008K bytes
Backlight2711-NL2
Communication Cable2711-NC13
Shipping Weight8 lbs.
Shipping Dimensions16 x 14 x 8 in
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-T9C9L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T9C9L1 units instead of migration.

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-T9C9L1
Product LinePanelview 900
Display Size9 in.
Display ColorColor
Input TypeTouchscreen
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 VDC
SoftwarePanelbuilder 32
Memory1008K bytes
Backlight2711-NL2
Communication Cable2711-NC13
Shipping Weight8 lbs.
Shipping Dimensions16 x 14 x 8 in
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-T9C9L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T9C9L1 units instead of migration.

s

About 2711-T9C9L1

The Allen-Bradley 2711-T9C9L1 PanelView 900 Color Terminal uses an RS-232 (DH-485) as a communications port and an RS-232 as a printer port to communicate with other machines. Moreover, this HMI has an operating temperature of 32-131 °F and activates using 24V DC input voltage. This Allen-Bradley 2711-T9C9L1 PanelView Standard terminal has a display area of 171 mm x 130 mm or 6.73 in. x 5.12 in.

The 2711-T9C9L1 is a part of the Allen-Bradley PanelView Standard 900 Color Series that offers a touchscreen as its input type. The 384 touch cells (24 columns x 16 rows) let the operator initiate functions by touching the screen. The 2711-T9C9L1 is 9-inch color flat panel touchscreen that weighs approximately 8 lbs. It measures 16 in. x 14 in. x 8 in. in dimension.

The 2711-T9C9L1 is an HMI with an application memory of 310 KB Runtime and an internal memory of 1008 KB which stores data, files, and applications. The 2711-T9C9L1 has a smooth navigation property with 2711-ND3 PanelBuilder 32 software that runs on a personal computer and operates in Basic English. This 32-bit software enables uploading and downloading applications from a computer, over the network, or by using a memory card. In line with this, it can be operated on the Microsoft Windows 2000, ME, XP, or Vista operating systems. 



Repair Services for 2711-T9C9L1

Type Lead Time Price Action
Repair Service 2-4 weeks $2304.35cartAdd to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or surplus unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures

Revisions for 2711-T9C9L1

Please refer to the manual for more information about the 2711-T9C9L1 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-T9C9L1/A, Series A, Rev A Request Quote
2711-T9C9L1X
2711-T9C9L1/X, Series X, Rev X Request Quote
Firmware Revisions

The 2711-T9C9L1 has several firmware revisions: 2711-T9C9L1-FRN 1.00, 2711-T9C9L1-FRN 1.03, 2711-T9C9L1-FRN 1.07, 2711-T9C9L1-FRN 2.00, 2711-T9C9L1-FRN 2.01, 2711-T9C9L1-FRN 2.02, 2711-T9C9L1-FRN 2.03, 2711-T9C9L1-FRN 3.00, 2711-T9C9L1-FRN 3.01, 2711-T9C9L1-FRN 3.02, 2711-T9C9L1-FRN 3.03, 2711-T9C9L1-FRN 3.13, 2711-T9C9L1-FRN 3.15, 2711-T9C9L1-FRN 3.30, 2711-T9C9L1-FRN 3.40, 2711-T9C9L1-FRN 4.00, 2711-T9C9L1-FRN 4.10, 2711-T9C9L1-FRN 4.20, 2711-T9C9L1-FRN 4.41, 2711-T9C9L1-FRN 4.46, and 2711-T9C9L1-FRN 4.48

Common misspellings:
  • 27l1-T9C9L1
  • 271l-T9C9L1
  • 2711-T9C911
  • 2711-T9C9Ll
  • 2711T9C9L1

Dimensions For 2711-T9C9L1

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 2711-T9C9L1

Resolutions For 2711-T9C9L1

About

Technical Specifications for 2711-T9C9L1

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-T9C9L1
Product LinePanelview 900
Display Size9 in.
Display ColorColor
Input TypeTouchscreen
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 VDC
SoftwarePanelbuilder 32
Memory1008K bytes
Backlight2711-NL2
Communication Cable2711-NC13
Shipping Weight8 lbs.
Shipping Dimensions16 x 14 x 8 in
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711-T9C9L1
Product LinePanelview 900
Display Size9 in.
Display ColorColor
Input TypeTouchscreen
CommunicationRS-232 (DH-485) and RS-232 Printer
Input Power24 VDC
SoftwarePanelbuilder 32
Memory1008K bytes
Backlight2711-NL2
Communication Cable2711-NC13
Shipping Weight8 lbs.
Shipping Dimensions16 x 14 x 8 in
Series A, B, C, D, E, F
Firmware1.00-4.48
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 2711-T9C9L1 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 2711-T9C9L1 units instead of migration.

About 2711-T9C9L1

The Allen-Bradley 2711-T9C9L1 PanelView 900 Color Terminal uses an RS-232 (DH-485) as a communications port and an RS-232 as a printer port to communicate with other machines. Moreover, this HMI has an operating temperature of 32-131 °F and activates using 24V DC input voltage. This Allen-Bradley 2711-T9C9L1 PanelView Standard terminal has a display area of 171 mm x 130 mm or 6.73 in. x 5.12 in.

The 2711-T9C9L1 is a part of the Allen-Bradley PanelView Standard 900 Color Series that offers a touchscreen as its input type. The 384 touch cells (24 columns x 16 rows) let the operator initiate functions by touching the screen. The 2711-T9C9L1 is 9-inch color flat panel touchscreen that weighs approximately 8 lbs. It measures 16 in. x 14 in. x 8 in. in dimension.

The 2711-T9C9L1 is an HMI with an application memory of 310 KB Runtime and an internal memory of 1008 KB which stores data, files, and applications. The 2711-T9C9L1 has a smooth navigation property with 2711-ND3 PanelBuilder 32 software that runs on a personal computer and operates in Basic English. This 32-bit software enables uploading and downloading applications from a computer, over the network, or by using a memory card. In line with this, it can be operated on the Microsoft Windows 2000, ME, XP, or Vista operating systems. 



Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $2304.35cartAdd to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or surplus unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Type Lead Time Price Action
Repair Service 2-4 weeks $2304.35cartAdd to Cart

We can Repair your Panelview 900

We have a team of highly trained technicians that can repair your panelview quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

Repair Turnaround of 3-5 Days for Most Panelviews

  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or surplus unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • RepairCapabilities:

    Auto Verification and Self-Test Failures

    ERROR! FEHLER! ERREUR! ERRORE!

    • Error 1 STATIC RAM test
    • Error 2 Terminal searching for a file to download.
    • Error 10 Erase boot flash area.
    • Error 11 Copy boot code
    • Error 12 Boot code copy successful
    • Error 13 Boot code copy failed. Check for error after boot code is copied to the onboard flash EPROM.
    • Error 20 Erase firmware from flash EPROM
    • Error 21 Copy firmware to firmware flash memory
    • Error 22 Firmware copy successful
    • Error 23 Firmware copy failed
    • Error 24 Performed CRC base firmware check
    • Error 25 Firmware not compatible with boot code
    • Error 26 Firmware not compatible with hardware
    • Error 30 Watchdog test
    • Error 31 Stuck key test
    • Error 32 Real time clock test
    • Error 33 LCD RAM failed
    • Error 34 Performed CRC extended firmware check
    • Error 40 No executable code to run after boot
    • Error 50 Wrong memory card format
    • Error 60 CPU could not execute code

    We Can Repair Your Hardware failures including:

    • Communication Hardware Faults (Ethernet/IP, DH-485, DH+, ControlNet, and RS-232)
    • Broken Toushcreen/Keypads
    • Broken Glass
    • Displays (Dead/Dim/Lines/Missing Pixels)
    • Dead Backlights
    • Broken Housing/Bezel
    • Power Board Failures
Revisions

Please refer to the manual for more information about the 2711-T9C9L1 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711-T9C9L1/A, Series A, Rev A Request Quote
2711-T9C9L1X
2711-T9C9L1/X, Series X, Rev X Request Quote

Common misspellings:
  • 27l1-T9C9L1
  • 271l-T9C9L1
  • 2711-T9C911
  • 2711-T9C9Ll
  • 2711T9C9L1
PDF