2711P-T7C15B1

 
 
 
 
 
Rated 4.3 with 11 reviews

top legal disclaimer bottom legal disclaimer
credit cards accepted
better business bureau

2711P-T7C15B1

Description: Panelview Plus 700 Touchscreen 6.5 in Color Display with ControlNet Communication AC Power/DC Power Logic Module with 64MB
Available Now
Request a quote for 2711P-T7C15B1

Estimated price: $1899


Description: Panelview Plus 700 Touchscreen 6.5 in Color Display with ControlNet Communication AC Power/DC Power Logic Module with 64MB

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711P-T7C15B1.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.3 with 11 reviews

    Technical Specifications for 2711P-T7C15B1

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711P-T7C15B1
Product LinePanelview Plus 700
Display Size6.5 in.
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Input Power85-264 VAC and 18-32 VDC
SoftwareFactoryTalk View Machine Edition
Memory64 MB
Backlight2711P-RL7C
Communication Cable1747-KFC15A
Shipping Weight8 lbs.
Shipping Dimensions14 x 11 x 8 in
SeriesSeries A, B, C, D, E, F, G
Firmwarenot applicable
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711P-T7C15B1
Product LinePanelview Plus 700
Display Size6.5 in.
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Input Power85-264 VAC and 18-32 VDC
SoftwareFactoryTalk View Machine Edition
Memory64 MB
Backlight2711P-RL7C
Communication Cable1747-KFC15A
Shipping Weight8 lbs.
Shipping Dimensions14 x 11 x 8 in
SeriesSeries A, B, C, D, E, F, G
Firmwarenot applicable

About 2711P-T7C15B1

The discontinued Allen Bradley Panelview Plus 700 2711P-T7C15B1 is an operator terminal that enables the user to interface with their machine. This HMI has a 6.5 in. Color Display. This Panelview allows the user to connect using FactoryTalk View Machine Edition software and a ControlNet communication port with a 1747-KFC15A communication cable(s). The user is able to control the HMI using the Touchscreen to input information and data. This unit is powered using 85-264 VAC and 18-32 VDC power. This unit has the following internal memory: 64 MB. If applicable this unit has an internal backlight replacement part number of 2711P-RL7C. The approximate shipping weight and dimensions are 8 lbs. and 14 x 11 x 8 in. The most common Series are: Series A, B, C, D, E, F, G and the most common firmware is not applicable. The ControlNet terminals can connect to a single or multiple controllers on a ControlNet network. They support scheduled and unscheduled access to controller data They also support redundant cabling. The ControlNet terminals support symbolic CIP addressing when communicating to a ControlLogix system. Every terminal features a Network Access port for local access to the ControlNet network. Application files are easily downloaded or uploaded using PanelBuilder32 over the ControlNet link, directly via the on-board RS-232 printer port, or with a PC memory card.

FAQ for 2711P-T7C15B1

PanelView Plus is ideal for applications with a need to observe, change, and display information graphically. This allows operators to quickly understand the status of their application. PanelView Plus is programmed with RSView Studio Machine Edition. It combines the most beneficial features from the well-known Allen-Bradley PanelView Standard and PanelView HMI products, as well as adding new functionality. Some of the features include: multi-vendor communications, trending, expressions, data logging, animation, and RSView Studio direct browsing of RSLogix 5000 addresses. The new modular design makes the PanelView Plus a flexible, cost-effective terminal enabling OEMs, system integrators, and end users to choose, change, or upgrade components to satisfy differing application requirements. There are many advantages to choosing the Allen Bradley Panelview Plus such as: top rated environmental specifications, RSView ME advanced functionality, flexible communication options, modular design for flexibility, inventory reduction, and easy upgrades. There is a choice of multiple dimension TFT active matrix color displays with keypad, touch, and keypad/touch versions. Your investment in PanelView products is protected by the ability to import current PanelView Standard and PanelView “e” applications into RSView Studio. In addition, the PanelView Plus designs fits into current PanelView cutouts, so you don’t have to change your panel design. PanelView Plus can help save you time and money whether it is providing more functional options, shortening development time, or making potential maintenance simpler!

Repair Services for 2711P-T7C15B1

Type Lead Time Price Action
Repair Service 3-5 days Askenvelope Get Quote

We Can Repair Your Panelview Plus 700

We have a team of highly trained technicians that can repair your Panelview Plus quickly at a great low price. To get a repair quote call 1-800-730-0292 or email [email protected]. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelview Plus
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • All Repairs Come with Our 1-Year Warranty!

Repair Capabilities

We Can Repair Your Hardware Failures Including:

  • Communication Failures
  • Broken Toushcreens/Keypads
  • Broken Glass
  • Displays (Dead/Dim/Lines/Missing Pixels)
  • Dead Backlights
  • Broken Housing/Bezel
  • Power Board Failures

Start UP Error Codes and Messages:

  • RAM Test- Error 1
  • Internal CF- Error 23
  • CRC Check- Error 24
  • Watchdog Test- Error 30
  • Stuck Key- Error 31
  • Stuck Touch- Error 31.5
  • Battery Test- Error 32
  • NVRAM Access- Error 33.5
  • EXE Check- Error 40
  • External CF- Error 50

Revisions for 2711P-T7C15B1

Please refer to the manual for more information about the 2711P-T7C15B1 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711P-T7C15B1/A, Series A, Rev A Request Quote
2711P-T7C15B1X
2711P-T7C15B1/X, Series X, Rev X Request Quote
Common misspellings:
  • 27l1P-T7C15B1
  • 271lP-T7C15B1
  • 2711P-T7Cl5B1
  • 2711P-T7C1581
  • 2711P-T7C15Bl
Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711P-T7C15B1
Product LinePanelview Plus 700
Display Size6.5 in.
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Input Power85-264 VAC and 18-32 VDC
SoftwareFactoryTalk View Machine Edition
Memory64 MB
Backlight2711P-RL7C
Communication Cable1747-KFC15A
Shipping Weight8 lbs.
Shipping Dimensions14 x 11 x 8 in
SeriesSeries A, B, C, D, E, F, G
Firmwarenot applicable
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.2711P-T7C15B1
Product LinePanelview Plus 700
Display Size6.5 in.
Display ColorColor
Input TypeTouchscreen
CommunicationControlNet
Input Power85-264 VAC and 18-32 VDC
SoftwareFactoryTalk View Machine Edition
Memory64 MB
Backlight2711P-RL7C
Communication Cable1747-KFC15A
Shipping Weight8 lbs.
Shipping Dimensions14 x 11 x 8 in
SeriesSeries A, B, C, D, E, F, G
Firmwarenot applicable
About
The discontinued Allen Bradley Panelview Plus 700 2711P-T7C15B1 is an operator terminal that enables the user to interface with their machine. This HMI has a 6.5 in. Color Display. This Panelview allows the user to connect using FactoryTalk View Machine Edition software and a ControlNet communication port with a 1747-KFC15A communication cable(s). The user is able to control the HMI using the Touchscreen to input information and data. This unit is powered using 85-264 VAC and 18-32 VDC power. This unit has the following internal memory: 64 MB. If applicable this unit has an internal backlight replacement part number of 2711P-RL7C. The approximate shipping weight and dimensions are 8 lbs. and 14 x 11 x 8 in. The most common Series are: Series A, B, C, D, E, F, G and the most common firmware is not applicable. The ControlNet terminals can connect to a single or multiple controllers on a ControlNet network. They support scheduled and unscheduled access to controller data They also support redundant cabling. The ControlNet terminals support symbolic CIP addressing when communicating to a ControlLogix system. Every terminal features a Network Access port for local access to the ControlNet network. Application files are easily downloaded or uploaded using PanelBuilder32 over the ControlNet link, directly via the on-board RS-232 printer port, or with a PC memory card.
FAQ
PanelView Plus is ideal for applications with a need to observe, change, and display information graphically. This allows operators to quickly understand the status of their application. PanelView Plus is programmed with RSView Studio Machine Edition. It combines the most beneficial features from the well-known Allen-Bradley PanelView Standard and PanelView HMI products, as well as adding new functionality. Some of the features include: multi-vendor communications, trending, expressions, data logging, animation, and RSView Studio direct browsing of RSLogix 5000 addresses. The new modular design makes the PanelView Plus a flexible, cost-effective terminal enabling OEMs, system integrators, and end users to choose, change, or upgrade components to satisfy differing application requirements. There are many advantages to choosing the Allen Bradley Panelview Plus such as: top rated environmental specifications, RSView ME advanced functionality, flexible communication options, modular design for flexibility, inventory reduction, and easy upgrades. There is a choice of multiple dimension TFT active matrix color displays with keypad, touch, and keypad/touch versions. Your investment in PanelView products is protected by the ability to import current PanelView Standard and PanelView “e” applications into RSView Studio. In addition, the PanelView Plus designs fits into current PanelView cutouts, so you don’t have to change your panel design. PanelView Plus can help save you time and money whether it is providing more functional options, shortening development time, or making potential maintenance simpler!
Repairs
Type Lead Time Price Action
Repair Service 3-5 days Askenvelope Get Quote

We Can Repair Your Panelview Plus 700

We have a team of highly trained technicians that can repair your Panelview Plus quickly at a great low price. To get a repair quote call 1-800-730-0292 or email [email protected]. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelview Plus
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • All Repairs Come with Our 1-Year Warranty!

Repair Capabilities

We Can Repair Your Hardware Failures Including:

  • Communication Failures
  • Broken Toushcreens/Keypads
  • Broken Glass
  • Displays (Dead/Dim/Lines/Missing Pixels)
  • Dead Backlights
  • Broken Housing/Bezel
  • Power Board Failures

Start UP Error Codes and Messages:

  • RAM Test- Error 1
  • Internal CF- Error 23
  • CRC Check- Error 24
  • Watchdog Test- Error 30
  • Stuck Key- Error 31
  • Stuck Touch- Error 31.5
  • Battery Test- Error 32
  • NVRAM Access- Error 33.5
  • EXE Check- Error 40
  • External CF- Error 50
Type Lead Time Price Action
Repair Service 3-5 days Askenvelope Get Quote

We Can Repair Your Panelview Plus 700

We have a team of highly trained technicians that can repair your Panelview Plus quickly at a great low price. To get a repair quote call 1-800-730-0292 or email [email protected]. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelview Plus
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • All Repairs Come with Our 1-Year Warranty!

Repair Capabilities

We Can Repair Your Hardware Failures Including:

  • Communication Failures
  • Broken Toushcreens/Keypads
  • Broken Glass
  • Displays (Dead/Dim/Lines/Missing Pixels)
  • Dead Backlights
  • Broken Housing/Bezel
  • Power Board Failures

Start UP Error Codes and Messages:

  • RAM Test- Error 1
  • Internal CF- Error 23
  • CRC Check- Error 24
  • Watchdog Test- Error 30
  • Stuck Key- Error 31
  • Stuck Touch- Error 31.5
  • Battery Test- Error 32
  • NVRAM Access- Error 33.5
  • EXE Check- Error 40
  • External CF- Error 50
Revisions

Please refer to the manual for more information about the 2711P-T7C15B1 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
2711P-T7C15B1/A, Series A, Rev A Request Quote
2711P-T7C15B1X
2711P-T7C15B1/X, Series X, Rev X Request Quote

Common misspellings:
  • 27l1P-T7C15B1
  • 271lP-T7C15B1
  • 2711P-T7Cl5B1
  • 2711P-T7C1581
  • 2711P-T7C15Bl
PDF