Product image is representative; revision or series may vary. Contact us to request a specific version.
The Eaton Cutler-Hammer 15CLE-150E fuse is designed as a medium-voltage current-limiting power fuse. Functioning at a rated voltage of 15.5 kV, it is rated for a current capacity of 150 A and features an interrupting rating of 63 kAIC, covering various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Medium-Voltage Current-Limiting Power Fuse |
| Product Line | Bussman |
| Part Number | 15CLE-150E |
| Rated Voltage (KV) | 15.5 kV |
| Rated Current | 150 A |
| Interrupting Rating | 63 kAIC |
| Application | Feeder circuits, metal-enclosed switchgear, switches, and transformer primary protection |
| Minimum Operating Temperature | -40°C |
| Maximum Operating Temperature | 40°C |
| Minimum Storage Temperature | -40°C |
| Maximum Storage Temperature | 70°C |
| Minimum Relative Humidity | 0% (Non-Condensing) |
| Maximum Relative Humidity | 95% (Non-Condensing) |
| Installation Altitude | 2000 m |
The 15CLE-150E model from Eaton Cutler-Hammer is a medium-voltage current-limiting power fuse specifically engineered for demanding protective applications. It has a rated voltage capability of 15.5 kV and can handle a continuous current of 150 A. This fuse is particularly beneficial in scenarios requiring high interrupting capacity, rated at 63 kAIC, ensuring a reliable response to fault conditions. Its applications extend to feeder circuits, providing essential protection for various metal-enclosed switchgear, switches, and transformer primary circuits. Operation is feasible over a broad temperature range, with a minimum operating threshold of -40°C and a maximum of 40°C, making it suitable for diverse environmental conditions. Storage of the fuse is also flexible, allowing temperatures from -40°C up to 70°C, ensuring functionality even after extended periods in challenging environments. The fuse is built to perform within a relative humidity range from 0% to 95%, reflecting its robustness in non-condensing settings. It is important to note that the installation altitude should not exceed 2000 meters to maintain optimal performance.