Free UPS Ground on All Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer Freedom Series AN16KN0A

Product image is representative; revision or series may vary. Contact us to request a specific version.

AN16KN0A

|

The Eaton Cutler-Hammer AN16KN0A is a robust motor control starter designed for full voltage non-reversing applications. It is classified under the Freedom Series and supports a rated continuous current of up to 90 A.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for AN16KN0A

ManufacturerEaton Cutler-Hammer
Product TypeMotor Control Starter (Full Voltage Non-Reversing)
Product LineFreedom Series
Part NumberAN16KN0A
Weight11.00 lbs (4.99 kg)
UPC782113603896
NEMA SizeSize 3
Rated Continuous Current90 A
Coil Voltage (AC)120 V @ 60 Hz
Coil Voltage (AC alternate)110 V @ 50 Hz
Number of Poles3 Poles
Auxiliary Contacts1 NO
Mounting OrientationHorizontal
Enclosure TypeOpen
Overload Relay TypeC306 Bi-metal
Interrupting Capacity10 kA
Motor FLA RangeHeaters purchased separately
Control Circuit TypeAC coil
Contact ConfigurationNon-reversing

The AN16KN0A model from Eaton Cutler-Hammer is engineered as a motor control starter specifically for full voltage applications without reversing capabilities. This unit is rated for continuous current up to 90 Amps and falls under the NEMA Size 3 classification, indicating its capability to operate in demanding industrial environments. The coil voltage specifications allow it to function with 120 volts AC at 60 Hz or with 110 volts AC at 50 Hz, offering flexibility for diverse installations.

In terms of configuration, it features a total of three poles and provides a single normally open auxiliary contact, enabling additional control functionalities. The starter is mounted horizontally, making it adaptable to various panel designs and layouts. The open enclosure type ensures adequate accessibility for maintenance and monitoring. Furthermore, it incorporates a C306 bi-metal overload relay type, enhancing protection against motor overload conditions.

With an interrupting capacity of 10 kA, this starter can safely manage short-circuit conditions, providing reliable operations in critical applications. It is important to note that the motor full-load amperage (FLA) range requires separate heater purchases to ensure optimal current handling. The control circuit is designed utilizing an AC coil, which further simplifies the control design and integration into existing electrical systems.