Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the S801T24N3S. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Brand | Eaton Cutler-Hammer |
Part Number | S801T24N3S |
Manufacturer | Eaton |
Description | Soft Starter |
Nominal Load Voltage: | 208/240/380/480/575 Volts AC |
Max Current: | 240 Amps |
Control Voltage: | 24 VDC |
Input Voltage Range: | 200 to 600 Volts AC |
Output power @ 200/208V 3PH: | 75 Horsepower |
Output power @ 230/240V 3PH: | 200 Horsepower |
Connection Type: | In-Line |
Internal Bypass: | Yes |
Overload Capacity: | 450% for 30 Seconds |
Product Type | Open Soft Starter |
Series | S801 |
Soft Starter Type | Non-combination |
Amps | 240 |
Option | No |
Poles | 3 |
Type | Standard |
Operating Frequency | 47-63 Hz |
Insulating voltage (Ui) | 660V AC |
Bypass mechanical lifespan | 10M |
Voltage AC | 240 max. |
Voltage DC | 120 max. |
Brand | Eaton Cutler-Hammer |
Part Number | S801T24N3S |
Manufacturer | Eaton |
Description | Soft Starter |
Nominal Load Voltage: | 208/240/380/480/575 Volts AC |
Max Current: | 240 Amps |
Control Voltage: | 24 VDC |
Input Voltage Range: | 200 to 600 Volts AC |
Output power @ 200/208V 3PH: | 75 Horsepower |
Output power @ 230/240V 3PH: | 200 Horsepower |
Connection Type: | In-Line |
Internal Bypass: | Yes |
Overload Capacity: | 450% for 30 Seconds |
Product Type | Open Soft Starter |
Series | S801 |
Soft Starter Type | Non-combination |
Amps | 240 |
Option | No |
Poles | 3 |
Type | Standard |
Operating Frequency | 47-63 Hz |
Insulating voltage (Ui) | 660V AC |
Bypass mechanical lifespan | 10M |
Voltage AC | 240 max. |
Voltage DC | 120 max. |
The S801T24N3S soft starter by Eaton Cutler-Hammer is a high-performance multifunctional soft starter from the S801 series of reduced voltage soft starters that are designed to control the acceleration and deceleration of 3-phase motors in industrial applications. This soft starter features a very compact design that allows for easy installation, and this small design makes it easy to retrofit into an existing motor control enclosure and this reduces replacement costs. The S801T24N3S soft starter has a maximum carrying current of 240 Amps, with an operating voltage range of 200 to 600 Volts AC and a standard duty output power rating of 125 Horsepower. It has programmable overload range of 30 to 100% of the rated current, and an insulation voltage rating of 660 Volts AC. The S801T24N3S soft starter provides a wide range of factory default protection like the over-temperature protection that protects the device from overheating, the shorted SCR detection that monitors the starter for shorted SCRs, and the soft stop functionality that allows for controlled stopping when a high-friction load is involved. The S801T24N3S soft starter also features user-selectable functionalities like the stall protection, jam protection, and phase loss protection that allows the device to trip in the event of voltage loss in any of the phases. The S801T24N3S soft starter has a 3-pole design, and it also has 24 Volts DC control voltage for enhanced operator safety. This soft starter can be installed or retrofitted into an enclosure by using mounting plates and it requires a factory-provided lead lug kit for easy field wiring. The S801T24N3S soft starter has an operating temperature range between -30 and 50 degrees Celsius, and a storage temperature range of -50 to 70 degrees Celsius.
The S801+T24N3S is a motor soft starter device that is manufactured by Eaton Corporation. This device is a panel mounted device and comes with a compact hardware. It belongs to the S801+ series of reduced voltage soft starters. It has programmable parameters, mainly featuring configurable starting and stopping functions such as Voltage limiting, Current limiting, Ramping, Soft start and Soft stop functions.
The S801+T24N3S’s operational voltage is 200-600 VAC with frequency of 47-63 Hz. It has output current of 240 Amperes and output power that varies according to the input and configured mains voltage such as 75 HP @ 200/208V 3PH; 75 HP @ 230/240V 3PH; 200 HP @ 460/480V 3PH; 200 HP @ 575/600V 3PH. Additionally, the drive’s control circuit operates as 24VDC, nominal supply voltage.
The S801+T24N3S is a panel mounted soft starter device with built-in internal bypass and overload protection. It also has input terminals for hardwired STOP command, hardwired START command, Jog control, Overload disable upon START and Fault reset. For indication, the S801+T24N3S has One (1) Normally Open (N.O.) relay contact which can be connected to an external Pilot lamp to indicate internal bypass and a Fault relay which may also be connected to a Pilot lamp for soft starter fault.
The S801+T24N3S meets a variety of industry standards such as IEC/EN 60947-4-2, UL 508, CSA22.2-14-1995, GB14048 and carries agency approvals from CE, UL, CSA, C-Tick and CCC. It has IP20 protection rating and IP00 for wiring terminals. IP20 may be achieved when the terminals is installed with the optional terminal cover with part number SS-IP20-TU.
What are available O/O terminals to the S801+T24N3S?
The S801+T24N3S has input terminals for hardwired STOP command, hardwired START command, Jog control, Overload disable upon START and Fault reset. It also has One (1) Normally Open (N.O.) relay contact which can be connected to an external Pilot lamp to indicate internal bypass and a Fault relay which may also be connected to a Pilot lamp for soft starter fault.
Does the S801+T24N3S come with a Digital Interface Module (DIM)?
No. DIM is not provided as built-in unit to this device.
What is the protection rating of this device?
The S801+T24N3S has IP20 Protection rating and IP00 to the terminals. Full IP20 rating can be achieved if installed with a terminal cover,
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your S801T24N3S. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
"The S801+T24N3S is a reduced voltage type soft starter from Eaton Corporation. This is a compact and small form factor soft starter that supports direct panel mounting. If used with existing motors, the compact assembly of this drive benefits the user as it may be installed retrofitted easily. One disadvantage of this soft starter is the lack of embedded LCD Digital Interface Module (DIM) for easier user interface. Instead, this soft-starter is equipped with traditional rotary switches and LED indicators. " -DO Supply Tech
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Brand | Eaton Cutler-Hammer |
Part Number | S801T24N3S |
Manufacturer | Eaton |
Description | Soft Starter |
Nominal Load Voltage: | 208/240/380/480/575 Volts AC |
Max Current: | 240 Amps |
Control Voltage: | 24 VDC |
Input Voltage Range: | 200 to 600 Volts AC |
Output power @ 200/208V 3PH: | 75 Horsepower |
Output power @ 230/240V 3PH: | 200 Horsepower |
Connection Type: | In-Line |
Internal Bypass: | Yes |
Overload Capacity: | 450% for 30 Seconds |
Product Type | Open Soft Starter |
Series | S801 |
Soft Starter Type | Non-combination |
Amps | 240 |
Option | No |
Poles | 3 |
Type | Standard |
Operating Frequency | 47-63 Hz |
Insulating voltage (Ui) | 660V AC |
Bypass mechanical lifespan | 10M |
Voltage AC | 240 max. |
Voltage DC | 120 max. |
Brand | Eaton Cutler-Hammer |
Part Number | S801T24N3S |
Manufacturer | Eaton |
Description | Soft Starter |
Nominal Load Voltage: | 208/240/380/480/575 Volts AC |
Max Current: | 240 Amps |
Control Voltage: | 24 VDC |
Input Voltage Range: | 200 to 600 Volts AC |
Output power @ 200/208V 3PH: | 75 Horsepower |
Output power @ 230/240V 3PH: | 200 Horsepower |
Connection Type: | In-Line |
Internal Bypass: | Yes |
Overload Capacity: | 450% for 30 Seconds |
Product Type | Open Soft Starter |
Series | S801 |
Soft Starter Type | Non-combination |
Amps | 240 |
Option | No |
Poles | 3 |
Type | Standard |
Operating Frequency | 47-63 Hz |
Insulating voltage (Ui) | 660V AC |
Bypass mechanical lifespan | 10M |
Voltage AC | 240 max. |
Voltage DC | 120 max. |
The S801T24N3S soft starter by Eaton Cutler-Hammer is a high-performance multifunctional soft starter from the S801 series of reduced voltage soft starters that are designed to control the acceleration and deceleration of 3-phase motors in industrial applications. This soft starter features a very compact design that allows for easy installation, and this small design makes it easy to retrofit into an existing motor control enclosure and this reduces replacement costs. The S801T24N3S soft starter has a maximum carrying current of 240 Amps, with an operating voltage range of 200 to 600 Volts AC and a standard duty output power rating of 125 Horsepower. It has programmable overload range of 30 to 100% of the rated current, and an insulation voltage rating of 660 Volts AC. The S801T24N3S soft starter provides a wide range of factory default protection like the over-temperature protection that protects the device from overheating, the shorted SCR detection that monitors the starter for shorted SCRs, and the soft stop functionality that allows for controlled stopping when a high-friction load is involved. The S801T24N3S soft starter also features user-selectable functionalities like the stall protection, jam protection, and phase loss protection that allows the device to trip in the event of voltage loss in any of the phases. The S801T24N3S soft starter has a 3-pole design, and it also has 24 Volts DC control voltage for enhanced operator safety. This soft starter can be installed or retrofitted into an enclosure by using mounting plates and it requires a factory-provided lead lug kit for easy field wiring. The S801T24N3S soft starter has an operating temperature range between -30 and 50 degrees Celsius, and a storage temperature range of -50 to 70 degrees Celsius.
The S801+T24N3S is a motor soft starter device that is manufactured by Eaton Corporation. This device is a panel mounted device and comes with a compact hardware. It belongs to the S801+ series of reduced voltage soft starters. It has programmable parameters, mainly featuring configurable starting and stopping functions such as Voltage limiting, Current limiting, Ramping, Soft start and Soft stop functions.
The S801+T24N3S’s operational voltage is 200-600 VAC with frequency of 47-63 Hz. It has output current of 240 Amperes and output power that varies according to the input and configured mains voltage such as 75 HP @ 200/208V 3PH; 75 HP @ 230/240V 3PH; 200 HP @ 460/480V 3PH; 200 HP @ 575/600V 3PH. Additionally, the drive’s control circuit operates as 24VDC, nominal supply voltage.
The S801+T24N3S is a panel mounted soft starter device with built-in internal bypass and overload protection. It also has input terminals for hardwired STOP command, hardwired START command, Jog control, Overload disable upon START and Fault reset. For indication, the S801+T24N3S has One (1) Normally Open (N.O.) relay contact which can be connected to an external Pilot lamp to indicate internal bypass and a Fault relay which may also be connected to a Pilot lamp for soft starter fault.
The S801+T24N3S meets a variety of industry standards such as IEC/EN 60947-4-2, UL 508, CSA22.2-14-1995, GB14048 and carries agency approvals from CE, UL, CSA, C-Tick and CCC. It has IP20 protection rating and IP00 for wiring terminals. IP20 may be achieved when the terminals is installed with the optional terminal cover with part number SS-IP20-TU.
What are available O/O terminals to the S801+T24N3S?
The S801+T24N3S has input terminals for hardwired STOP command, hardwired START command, Jog control, Overload disable upon START and Fault reset. It also has One (1) Normally Open (N.O.) relay contact which can be connected to an external Pilot lamp to indicate internal bypass and a Fault relay which may also be connected to a Pilot lamp for soft starter fault.
Does the S801+T24N3S come with a Digital Interface Module (DIM)?
No. DIM is not provided as built-in unit to this device.
What is the protection rating of this device?
The S801+T24N3S has IP20 Protection rating and IP00 to the terminals. Full IP20 rating can be achieved if installed with a terminal cover,
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your S801T24N3S. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your S801T24N3S. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
"The S801+T24N3S is a reduced voltage type soft starter from Eaton Corporation. This is a compact and small form factor soft starter that supports direct panel mounting. If used with existing motors, the compact assembly of this drive benefits the user as it may be installed retrofitted easily. One disadvantage of this soft starter is the lack of embedded LCD Digital Interface Module (DIM) for easier user interface. Instead, this soft-starter is equipped with traditional rotary switches and LED indicators. " -DO Supply Tech