Free UPS Ground on All Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer W200 Drives W200M2CFC

Product image is representative; revision or series may vary. Contact us to request a specific version.

W200M2CFC

|

The W200M2CFC is a 3-Phase, Non-Reversing Magnetic Motor Starter that is manufactured by Eaton / Cutler Hammer. This is part of the advantage series that is designed for motor voltage of 200 Volts AC, 200-575 Volts AC, 3-Phase and coil voltage of 120 Volts AC @ 60 Hertz and 110 Volts AC @ 50 Hertz. It has a continuous output current of 45 Amperes with an output power of Horsepower @ 200 Volts AC; 15 Horsepower @ 230 Volts AC and 25 Horsepower @ 460 Volts AC and 575 Volts AC.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for W200M2CFC

ManufacturerEaton Cutler-Hammer
CategoryDrives
Product LineW200 Drives
Part NumberW200M2CFC
Weight45.00 lbs (20.41 kg)
SeriesAdvantage
Product DescriptionNon-reversing magnetic starter
SizeNEMA Size 2
Coil Voltage120 VAC @ 60 Hz; 110 VAC @ 50 Hz
Motor Voltage200 VAC; 230 VAC; 460 VAC; 575 VAC
Continuous output current45 A
Output power10 HP @ 200 VAC; 15 HP @ 230VAC and 25 HP @ 460 VAC and 575 VAC
No. of Poles3
Motor Protection FeaturesOverload; Ground current sensing; Phase unbalance; Phase Loss
Phase Trip setting1.15 A
Ground Current trip setting20 A
Overload ClassClass 10, 20, 30

The Eaton Corporation W200M2CFC module is a motor starter that belongs to the Advantage series.. Generally, it is suitable for motors that require a starter with overload protection, phase loss, and imbalance protection, among other protective features. The Eaton Corporation W200M2CFC motor starter operates with a coil voltage of 120 Volts and a frequency of 50 to 60 Hertz. It also has a continuous amperage rating of 45 Amps. The Eaton Corporation W200M2CFC motor starter has been categorized as a NEMA size 2 starter in the Advantage series.

This starter has an open type of enclosure that protects its essential wiring from contact with the users. It also enables the controller to withstand a higher temperature than regular enclosures can. The Eaton Corporation W200M2CFC motor starter works with 3-phase motors and it provides a Horsepower rating of 10 Horsepower at a specific voltage of 200 Volts. The Eaton Corporation W200M2CFC motor starter is a non-reversing controller. This means that it can be applied to a motor with an existent contactor that cannot be reversed. In order to enable the complete functioning of the motor, a controller of this kind must be applied and installed. This controller provides a means for starting and stopping the motor. It provides an emergency stop button and the control wiring will depend on the current use of the drive, specifically on whether it is using its communications functions or not.

The W200M2CFC is a non-reversing motor starter from the Cutler Hammer / Eaton Corporation. This is part of the Advantage series that features a coil voltage of 120 Volts AC @ 60 Hertz and 110 Volts AC @ 50 Hertz frequency. It has power output of 10 Horsepower @ 200 Volts AC; 15 Horsepower @ 230 Volts AC and 25 Horsepower @ 460 Volts AC and 575 Volts AC and continuous output current of 45 Amperes.

The W200M2CFC is a NEMA size 2 starter and is provided with ground current sensing protection wherein a factory-set low level and a lockout current is defined. This feature opens the circuit when low-level and arcing ground current is detected. This feature is standard to all members of the Advantage series such as the W200M2CFC; however, this can be modified or omitted through the Advantage Programming Module (WAPM). This feature is not a substitute for Ground Fault Circuit Interrupters (GFCI). For the W200M2CFC, ground current sensing is set at 10 Amperes, lockout current at 86 Amperes, with trip time of 0.4 seconds.

Aside from the Ground Current Sensing protection, the W200M2CFC also features Phase unbalance detection wherein at 30% unbalance of the trip rating of the starter in any 2 phases is detected, triggers starter trip. Similarly, this is a standard feature that can be deactivated using the WAPM. Another built-in protective feature available to the W200M2CFC is the Phase Loss feature starter trip is triggered when Phase Loss is detected. This happens when current in any one of the phase is lower than 1.15 Amperes. This error has an internal time delay of 2 seconds. This may also be disabled using the WAPM.