Product image is representative; revision or series may vary. Contact us to request a specific version.
The Eaton Cutler-Hammer BRN240GF serves as a reliable ground fault circuit breaker. With a dual pole design, this unit is rated for 40 Amperes and operates effectively at 120/240 Volts AC. Its thermal-magnetic trip mechanism offers protection with a trip sensitivity of 5 mA, ensuring personnel safety against ground faults.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Ground Fault Circuit Breaker |
| Product Line | BR Circuit Breakers |
| Part Number | BRN240GF |
| GTIN | 00 786676043786 |
| Poles | 2 Poles |
| Amperage Rating | 40 Amperes |
| Voltage Rating | 120/240 Volts AC |
| Interrupt Rating | 10 kAIC |
| Trip Mechanism | Thermal-magnetic |
| Trip Sensitivity | 5 mA |
| Neutral Connection | Pigtail |
| Wire Size | 14-4 AWG |
| Protection Function | Ground Fault Circuit Interrupter Personnel Protection |
| Trip Type | Common Trip |
| Certification | UL 489, UL 943, CSA |
| Operating Temperature | -35 to 66 degrees Celsius |
The part number BRN240GF by Eaton Cutler-Hammer is designed specifically as a ground fault circuit breaker, featuring a two-pole configuration. Its operational capabilities include an amperage rating of 40 Amperes, facilitating a voltage rating of 120/240 Volts AC. This circuit breaker incorporates a thermal-magnetic trip mechanism that ensures reliable performance under various fault conditions.
The unit's sensitivity is set at 5 mA, promoting personnel protection by detecting ground faults effectively. Additionally, it comes with a common trip mechanism that enhances the safety of connected circuits. The device boasts an interrupt rating of 10 kAIC, allowing it to handle fault currents up to this level safely.
For connection purposes, a pigtail is integrated for the neutral connection, which provides a straightforward installation option. A wide range of wire sizes from 14 AWG to 4 AWG is supported, making it versatile for different applications.
This ground fault circuit breaker has been certified by UL 489, UL 943, and CSA, ensuring it meets rigorous safety standards. Furthermore, it is built to operate effectively within an ambient temperature range of -35 to 66 degrees Celsius, making it suitable for various environmental conditions.