Product image is representative; revision or series may vary. Contact us to request a specific version.
The FAZ-C3/2-NA from Eaton Cutler-Hammer is a miniature circuit breaker with a current rate of 3.0 A. This device has two poles and is designed to operate within an AC voltage range of 277 to 480 Y V and a DC voltage of 96 V.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Miniature Circuit Breaker |
| Product Line | FAZ Series |
| Part Number | FAZ-C3/2-NA |
| Number of Poles | 2 Poles |
| Continuous Current Rating | 3.0 A |
| Tripping Characteristic | C Curve |
| Voltage Rating (AC) | 277/480 Y V AC |
| Voltage Rating (DC) | 96 V DC |
| Interrupting Capacity (UL 489) | 10 kAIC |
| Trip Unit Mechanism | Thermal-Magnetic |
| Mounting Type | 35mm DIN Rail Mount |
| Terminal Interface | Twin-purpose Box Lugs |
| Min. Operating Temperature | -25 °C |
| Max. Operating Temperature | 75 °C |
The Eaton Cutler-Hammer FAZ-C3/2-NA model is a miniature circuit breaker engineered to cover a range of specifications for effective circuit protection. With a continuous current rating of 3.0 A, it features a two-pole design that allows for reliable operation in residential or industrial electrical systems. This breaker supports both AC and DC voltages, rated at 277/480 Y V for the former and 96 V for the latter, ensuring compatibility with various applications.
Operating with a C curve tripping characteristic, this device is adept at managing transient inrush currents commonly encountered during the start-up of motors or other inductive loads. Additionally, the thermal-magnetic trip unit offers both thermal and instantaneous protection, safeguarding against overloads and short circuits.
The FAZ-C3/2-NA has a UL 489 rated interrupting capacity of 10 kAIC, indicating its capability to interrupt fault currents effectively, thereby protecting the electrical circuit from potential damage. For installation, it is structured for mounting on a 35mm DIN rail, making it convenient for space-constrained panel setups. The twin-purpose box lugs simplify the wiring process, accommodating various types of connections.
Effective operation is maintained across a temperature range, with a minimum of -25 °C and a maximum of 75 °C. This makes the FAZ-C3/2-NA particularly suitable for diverse environments where such temperature variations might occur.