The PDG22M0125TFFJ from Eaton Cutler-Hammer is designed as a molded case circuit breaker. It has a rated current of 125 A and operates under voltage ratings of up to 600 VAC and 250 VDC. With a weight of 4.5 lbs, it is configured with two poles and features thermal-magnetic trip technology with long-time and instantaneous trip functions.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Power Defense |
| Part Number | PDG22M0125TFFJ |
| Weight | 72.00 lbs (32.66 kg) |
| UPC | 786679247518 |
| Rated Current | 125 A |
| Voltage Rating (AC) | 600 VAC |
| Voltage Rating (DC) | 250 VDC |
| Number of Poles | 2 Poles |
| Interrupting Capacity (AIC) at 480 VAC | 65 kAIC |
| Interrupting Capacity (AIC) at 240 VAC | 100 kAIC |
| Interrupting Capacity (AIC) at 600 VAC | 35 kAIC |
| Trip Type | Thermal-Magnetic |
| Trip Functions | LI (Long-Time and Instantaneous) |
The Eaton Cutler-Hammer PDG22M0125TFFJ is a molded case circuit breaker optimized for robust electrical management. It is rated for a maximum current of 125 A and supports voltage ratings of 600 VAC and 250 VDC, effectively accommodating various applications. This circuit breaker, weighing 4.5 lbs, features a dual-pole configuration that allows for effective circuit control over multiple phases.
Configured with a thermal-magnetic trip type, this model provides reliable fault protection. It incorporates long-time and instantaneous trip functions denoted as LI, delivering swift responses to overload conditions. This functionality helps prevent potential damage to downstream devices. The interrupting capacities of the PDG22M0125TFFJ are notable. It can handle fault currents of up to 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at its maximum voltage rating of 600 VAC, offering peace of mind in high-load scenarios.