Product image is representative; revision or series may vary. Contact us to request a specific version.
The 12NC1200, produced by Eaton Cutler-Hammer, serves as a fixed rating plug within the Series C Circuit Breakers lineup. This rating plug is designed to operate effectively at a chosen current rating of 1200 A and supports AC voltage up to 600 VAC and DC voltage up to 250 VDC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Rating Plug |
| Product Line | Series C Circuit Breakers |
| Part Number | 12NC1200 |
| Weight | 0.06 lbs (0.03 kg) |
| UPC | 786679150542 |
| Plug Type | Fixed Rating Plug |
| Compatibility Rated Current | 1200 A |
| Voltage Rating (AC) | 600 VAC |
| Voltage Rating (DC) | 250 VDC |
| Compatible Breaker Frames | NC, NCA, NCG, NCGA, HNC, HNCA, HNCG, HNCGA Frames |
| Magnetic Trip Range | 2400 A to 9600 A |
| Number of Poles Compatibility | 2-Poles / 3-Poles |
| Min. Operating Temperature | -20°C |
| Max. Operating Temperature | 55°C |
| Min. Storage Temperature | -30°C |
| Max. Storage Temperature | 70°C |
The Eaton Cutler-Hammer part number 12NC1200 is classified as a fixed rating plug designed for use with various Series C Circuit Breakers. With a compatibility rating of up to 1200 A, this plug is engineered for electrical performance. It accommodates an AC rating of 600 VAC and a DC voltage of up to 250 VDC, ensuring versatility for different electrical applications.
This fixed rating plug works well with approved breaker frames, which include NC, NCA, NCG, NCGA, HNC, HNCA, HNCG, and HNCGA configurations. An important aspect of the 12NC1200 is its magnetic trip range. It can function effectively within a range of 2400 A to 9600 A, providing necessary protection against overloads while maintaining operational integrity.
The unit is suited for both 2-pole and 3-pole breakers, offering flexibility in setup. Ambient conditions must be considered; the device operates efficiently within a temperature range starting at -20°C and up to 55°C. When considering storage, it can withstand temperatures as low as -30°C and as high as 70°C, allowing for a wide range of environmental conditions.