Eaton Cutler-Hammer Series C Circuit Breakers ELC3100

Product image is representative; revision or series may vary. Contact us to request a specific version.

ELC3100

|

The ELC3100 from Eaton Cutler-Hammer is a current limiter attachment designed specifically for use with 100A HMCP motor circuit protectors. It operates at a maximum voltage of 600 V AC and features a robust interrupting rating of 200,000 A (Sym) at that voltage.

Available Now
2 Year DO Supply Warranty
In Stock
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for ELC3100

ManufacturerEaton Cutler-Hammer
Product TypeCurrent Limiter Attachment
Product LineSeries C Circuit Breakers
Part NumberELC3100
UPC786679161197
Device Compatibility100A HMCP (Motor Circuit Protectors)
Amperage Rating100A
Voltage Rating600 V AC
Interrupting Rating200,000 A (Sym) @ 600 V AC
Number of Poles3 Poles
Conductor Material CompatibilityCopper (CU) or Aluminum (AL)
Wire Size Range#4 to 4/0 AWG (CU/AL)
Fault IndicatorPlunger-type extension indicator
Insulation RequirementRequires .031-inch thick fiber insulation under limiter
Min. Frequency50 Hz
Max. Frequency60 Hz

The ELC3100 Current Limiter Attachment is a product from Eaton Cutler-Hammer’s Series C Circuit Breakers line. This component is specifically designed for compatibility with 100A HMCP (Motor Circuit Protectors), ensuring effective integration within existing systems. It supports an amperage rating of 100A and can operate with a voltage rating of up to 600 V AC, allowing it to meet demanding electrical specifications.

With an interrupting rating of 200,000 A (Sym) at 600 V AC, the ELC3100 provides significant protection against overcurrent scenarios, mitigating potential circuit failures. This attachment consists of three poles, featuring robust design considerations for reliable operation. The current limiter can handle conductors made of either copper (CU) or aluminum (AL), with an accommodating wire size range from #4 to 4/0 AWG.

In terms of fault detection, the unit includes a plunger-type extension indicator that effectively signals when a fault occurs. Additionally, the attachment must be installed with a .031-inch thick fiber insulation positioned beneath the limiter, ensuring compliance with insulation requirements. This device operates within a frequency range between 50 Hz and 60 Hz, making it well-suited for various applications in industrial settings.