The Eaton Cutler-Hammer FDC3030 is a molded case circuit breaker that operates at a trip current of 30 amperes. It utilizes a thermal magnetic trip unit and is rated for both 250 volts DC and 600 volts AC in a three-phase system.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for FDC3030

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Circuit Breaker
Product LineSeries C Circuit Breakers
Part NumberFDC3030
Weight4.50 lbs (2.04 kg)
UPC786679451465
Trip Current Rating30 Amperes
Type of Trip UnitThermal Magnetic
Connection TypeFeed-Thru
Protection FunctionsReverse Feed Functions
System Voltage250 Volts DC / 600 Volts AC
System Phase3-Phase
Load Side Terminal ConnectionLugs
Line Side Terminal ConnectionBusbar
Frame TypeF Frame
Maximum Interrupt Rating35 kA at 600 Volts AC and 22 kA at 250 Volts DC
System Frequency50 to 60 Hertz
Safety StandardsCSA-approved and UL-certified
Poles Quantity3 Poles

The FDC3030, a molded case circuit breaker from Eaton Cutler-Hammer's Series C, is engineered for effective load management. This unit is rated for a trip current of 30 Amperes and operates with a thermal magnetic trip unit to enhance protective measures against overloads and short circuits. It is capable of functioning in systems with a voltage range of 250 Volts DC and 600 Volts AC, making it well-suited for diverse applications.

The FDC3030 features a three-pole configuration, ensuring efficient distribution and management of current across a 3-phase system. This circuit breaker has a maximum interrupt rating of 35 kiloamperes at 600 volts AC and 22 kiloamperes at 250 volts DC, ensuring reliability under fault conditions.

The load side terminal connection is achieved through lugs, while a busbar connection is implemented on the line side, enhancing installation flexibility. Operating at a frequency of 50 to 60 Hertz, this breaker meets rigorous CSA and UL certifications, ensuring compliance with established safety standards. The frame size is categorized as F, supporting its robust design suitable for various mounting configurations.