Product image is representative; revision or series may vary. Contact us to request a specific version.
The FDC3150 from Eaton Cutler-Hammer is a molded case circuit breaker tailored for efficient electrical distribution. With a weight of 4.25 lbs, this unit operates effectively in three-phase systems at rated currents up to 150 A and voltages of 600 VAC in alternating current and 250 VDC in direct current applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series C Circuit Breakers |
| Part Number | FDC3150 |
| Weight | 4.25 lbs (1.93 kg) |
| UPC | 786679451663 |
| Frame Type | F-Frame |
| Interrupting Rating (AIC) at 240 VAC | 200 kAIC |
| Interrupting Rating (AIC) at 480 VAC | 100 kAIC |
| Interrupting Rating (AIC) at 250 VDC | 22 kAIC |
| Protection Function | LI (Long-Time and Instantaneous) |
| Trip Type | Fixed Thermal, Fixed Magnetic |
| Phase Type | 3 Phase |
| Number of Poles | 3 Poles |
| Rated Current | 150 A |
| Voltage Rating (AC) | 600 VAC |
| Voltage Rating (DC) | 250 VDC |
The Eaton Cutler-Hammer FDC3150 circuit breaker is designed to deliver dependable electrical protection for a variety of applications. This molded case circuit breaker operates at a rated current of 150 A and excels in environments requiring three-phase power management. It has voltage ratings of 600 VAC for alternating current and 250 VDC for direct current, offering versatility across different systems.
Constructed with an F-frame design, this unit weighs 4.25 lbs and features three poles for enhanced circuit management. The trip mechanism leverages fixed thermal and fixed magnetic technology, ensuring both long-time and instantaneous protection, categorized under the LI function.
For durability and safety, the FDC3150 ensures substantial interrupting capacity. It can withstand fault currents up to 200 kAIC at 240 VAC and 100 kAIC at 480 VAC in AC systems. In DC applications, it maintains an interrupting capacity of 22 kAIC at 250 VDC, safeguarding connected equipment during fault conditions. The UPC for this breaker is 786679451663, facilitating inventory management and traceability.