The GHB2100 from Eaton Cutler-Hammer is a two-pole molded case circuit breaker designed for demanding electrical applications. With a rated current capacity of 100 A and a voltage rating of 480Y/277 VAC, this device balances functionality with reliability across various scenarios.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series C Circuit Breakers |
| Part Number | GHB2100 |
| Weight | 1.13 lbs (0.51 kg) |
| UPC | 786679911242 |
| Rated Voltage (AC) | 480Y/277 VAC |
| Rated Voltage (DC) | 125/250 VDC |
| Trip Type | T186 trip |
| Frame Size | Frame G |
| Min. Frequency | 50 Hz |
| Max. Frequency | 60 Hz |
| Number of Poles | 2 Poles |
| Interrupt Rating at 480Y/277 VAC | 14 kAIC |
| Rated Current | 100 A |
| Interrupt Rating at 240 VAC | 65 kAIC |
The Eaton Cutler-Hammer GHB2100 is engineered as a molded case circuit breaker, characterized by its robust design suitable for complex electrical protection needs. This particular circuit breaker functions effectively with a two-pole configuration and can manage a rated current of 100 A, ensuring adequate protection for circuits around this rating. It supports an input voltage of up to 480Y/277 VAC for alternating current systems and is also rated for direct current applications at 125/250 VDC.
The trip mechanism employed here is of the T186 type, which facilitates effective reaction times under fault conditions, thereby enhancing the safety of the electrical system. This breaker operates efficiently within a frequency range of 50 Hz to 60 Hz, providing versatility across varying electrical systems.
When considering interrupt ratings, the GHB2100 is equipped to handle fault currents of up to 14 kAIC at 480Y/277 VAC, alongside an adequate performance rating of 65 kAIC at 240 VAC. This means it can effectively manage and isolate faults, preventing potential damage and ensuring the safety of connected equipment. Its Frame G size designation further specifies its physical compatibility with various mounting environments, providing flexibility in installation. Overall, the GHB2100 combines reliable specifications with thoughtful design to meet the needs of demanding industrial applications.