Product image is representative; revision or series may vary. Contact us to request a specific version.
The Eaton Cutler-Hammer HFD3015L is a molded case circuit breaker designed for efficient protection in various electrical systems. Rated for 600 Volts AC and 250 Volts DC, it handles an amperage rating of 15 Amperes and operates within a frequency range of 50/60 Hz.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series C Circuit Breakers |
| Part Number | HFD3015L |
| Weight | 4.19 lbs (1.90 kg) |
| Frame | F-Frame |
| Voltage Rating | 600 Volts AC, 250 Volts DC |
| Amperage Rating | 15 Amperes |
| Terminals | Line and Load Lugs (Feed-Thru) |
| Frequency Rating | 50/60 Hz |
| Poles | 3-Pole |
| Phase | 3-Phase |
| Protection | Fixed Thermal, Fixed Magnetic |
| Interrupt Rating | 100 kAIC at 240 Vac, 65 kAIC at 480 Vac, 25 kAIC at 600 Volts AC |
| Wire Size Range | 14-1/0 AWG |
| Certifications | UL, CSA |
| Mounting | Fixed/Bolt On |
| Trip Functions | LI (Long-Time and Instantaneous) |
The HFD3015L from Eaton Cutler-Hammer's Series C Circuit Breakers is constructed as a molded case circuit breaker, tailored for reliable service in electrical systems. It comes with an F-frame design and is rated for a maximum voltage of 600 Volts AC alongside a 250 Volts DC capacity. The amperage is rated at 15 Amperes, providing adequate protection for various circuits.
Engineered to operate on a frequency of 50/60 Hz, this circuit breaker supports 3-pole configurations suitable for 3-phase setups. The HFD3015L includes terminals for line and load lugs, allowing for feed-thru wiring, and is compatible with wire sizes ranging from 14 to 1/0 AWG.
The protection system includes both fixed thermal and fixed magnetic functionalities, working in tandem to safeguard circuits effectively. Regarding its interrupt ratings, the device can handle 100 kAIC at 240 Vac, 65 kAIC at 480 Vac, and 25 kAIC at 600 Volts AC, ensuring safety during abnormal conditions. This model adheres to UL and CSA certifications for reliability and is designed for fixed or bolt-on mounting. The trip functions are categorized as LI (Long-Time and Instantaneous), allowing for effective responses to overload conditions.