Technical specifications for LD3350

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Circuit Breaker
Product LineSeries C Circuit Breakers
Part NumberLD3350
Weight21.00 lbs (9.53 kg)
UPC786679019030
Voltage Rating (AC)600 VAC
Voltage Rating (DC)250 VDC
Number of Poles3 Poles
Phase Type3 Phase
Rated Current350 A
Interrupting Rating (AIC) at 240 VAC65 kAIC
Interrupting Rating (AIC) at 480 VAC35 kAIC
Interrupting Rating (AIC) at 600 VAC25 kAIC
Interrupting Rating (AIC) at 250 VDC22 kAIC
Trip Unit TypeFixed Thermal, Fixed Magnetic
Trip FunctionsLI (Long-Time and Instantaneous)
Terminal TypeLine and Load side lugs

The part number LD3350 manufactured by Eaton Cutler-Hammer is classified as a molded case circuit breaker, engineered for reliable circuit protection in various electrical installations. This device operates effectively with an AC voltage rating of up to 600 volts and supports a DC voltage rating of 250 volts. Designed with three poles, this breaker is ideal for three-phase systems, which enhances its applicability across diverse scenarios.

The LD3350 is constructed to handle a continuous current of 350 amperes, ensuring it can manage substantial load demands. It boasts impressive interrupting capabilities, with ratings of 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. Such specifications are pivotal in leveraging the breaker’s ability to protect circuits against overloads and short-circuits efficiently.

In terms of functionality, the breaker employs a fixed thermal and fixed magnetic trip unit. This configuration enables it to perform both long-time and instantaneous trip functions, offering advanced protection for downstream equipment. Terminations are made through line and load side lugs, which simplify installation and enhance connectivity within electrical panels. The LD3350, with its UPC of 786679019030, integrates seamlessly into existing systems while adhering to safety and performance standards.