The LDC3500 model from Eaton Cutler-Hammer represents a robust molded case circuit breaker. Capable of accommodating three-phase systems, this breaker features an L-frame design and is rated for a maximum current of 500 Amps, with a versatile voltage rating of up to 600 VAC for AC applications and 250 VDC for DC settings.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series C Circuit Breakers |
| Part Number | LDC3500 |
| Weight | 21.00 lbs (9.53 kg) |
| Frame Size | L-Frame |
| Rated Current | 500 A |
| Number of Poles | 3 Poles |
| Phase Type | 3 Phase |
| Voltage Rating (AC) | 600 VAC |
| Voltage Rating (DC) | 250 VDC |
| Interrupting Capacity (240 VAC) | 65 kAIC |
| Interrupting Capacity (480 VAC) | 100 kAIC |
| Trip Functions | LI (Long-Time and Instantaneous) |
| Trip Unit Type | Thermal-Magnetic |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
The Eaton Cutler-Hammer LDC3500 is designed as a highly effective molded case circuit breaker. Engineered for three-phase electrical systems, it features an L-frame capacity and is rated for a current of 500 Amps. This model is capable of handling an input voltage of 600 VAC in AC scenarios and up to 250 VDC for direct current applications.
In terms of reliability, the LDC3500 showcases impressive interrupting capabilities, rated at 65 kAIC for circuits operating at 240 VAC and reaching up to 100 kAIC for 480 VAC applications. This makes it suitable for a range of industrial uses where high fault currents may occur. The breaker exhibits two significant trip functions: long-time (LI) and instantaneous, which enhances safety by responding appropriately to varying electrical conditions.
Reliability is further assured through a thermal-magnetic trip unit which offers precise operation under different load factors. Additionally, the unit functions optimally within a frequency range from 50 Hz to 60 Hz, ensuring compatibility with most industrial systems. The LDC3500 circuit breaker is a critical component for controlling electrical distribution, providing extensive protection and efficient performance in varied environments.