The Eaton Cutler-Hammer EGB3090FFG is a robust molded case circuit breaker designed for efficient power management. This unit is rated for voltages up to 600Y/347 Vac and provides a 90 A amperage capacity. Featuring a three-pole configuration, the EGB3090FFG ensures seamless operation in 3-phase systems.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series G Circuit Breakers |
| Part Number | EGB3090FFG |
| UPC | 782114876411 |
| Voltage Rating | 600Y/347 Vac |
| Amperage Rating | 90 A |
| Overload Protection | Provided by Thermal Element |
| Number of Poles | Three Poles |
| Frame Size | EG Frame |
| Trip Type | T186 |
| Terminals | Line and Load |
| Interrupt Rating | 18 kAIC at 480 Vac |
| Frequency Rating | 50-60 Hz |
| Mounting | Panelboard |
| Phase | 3-Phase |
| HACR Rated | Yes |
| Certification | UL Listed, CSA Certified, IEC Rated |
The EGB3090FFG from Eaton Cutler-Hammer is classified as a molded case circuit breaker. It is engineered to operate within a voltage rating of 600Y/347 Vac, making it suitable for various electrical applications. This circuit breaker is rated for an amperage of 90 A, allowing it to handle substantial loads effectively. It features a three-pole setup tailored for 3-phase systems, making it ideal for industrial environments.
Overload protection is managed through a thermal element, ensuring that the breaker trips in case of an overload condition. The trip type for this model is classified as T186, allowing for reliable performance. With terminals for both line and load, installation in panelboards is straightforward and secure.
For fault management, it has impressive interrupting capacities of 25 kAIC at 240 Vac and 18 kAIC at 480 Vac, making it effective in protecting circuits from high fault currents. The frequency rating is adaptable, supporting systems operating at 50-60 Hz.
Designed for practical use, this circuit breaker is HACR rated, which means it can be used in heating, air conditioning, and refrigeration applications. Additionally, it holds certifications confirming that it meets UL and CSA standards, as well as IEC ratings, ensuring its suitability and safety for use in various installations.