| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series G Circuit Breakers |
| Part Number | LGH3500FAG |
| Weight | 16.00 lbs (7.26 kg) |
| UPC | 782116142774 |
| Rated Current | 500 A |
| Voltage Rating | 600 VAC |
| Number of Poles | 3 Poles |
| Trip Type | Fixed Thermal, Adjustable Magnetic |
| Interrupting Capacity (AIC) at 240 VAC | 100 kAIC |
| Interrupting Capacity (AIC) at 480 VAC | 65 kAIC |
| Interrupting Capacity (AIC) at 600 VAC | 35 kAIC |
| Interrupting Capacity (AIC) at 415 VAC | 70 kAIC |
| Terminal Type | Line and Load |
The LGH3500FAG circuit breaker from Eaton Cutler-Hammer's Series G is a robust molded case circuit breaker specifically designed to handle significant current loads. With a rating of 500 A, this unit is suitable for managing electrical demands efficiently. It operates at a maximum voltage of 600 VAC across three poles, making it ideal for applications requiring three-phase power.
This design incorporates both fixed thermal and adjustable magnetic trip mechanisms, providing tailored protection based on the circuit environment. In terms of fault interruption, the LGH3500FAG can manage a substantial interrupting capacity. At 240 VAC, it has a capacity of 100 kAIC, while it is rated for 65 kAIC at 480 VAC and 35 kAIC at 600 VAC. For systems operating at 415 VAC, the breaker can interrupt currents of up to 70 kAIC, ensuring safety under fault conditions.