Product image is representative; revision or series may vary. Contact us to request a specific version.
The NGC312032EC from Eaton Cutler-Hammer is a molded case circuit breaker designed for robust power management. It supports a rated current of 1200 A and can accommodate both 480 VAC and 600 VAC systems.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Eaton Cutler-Hammer |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Series G Circuit Breakers |
| Part Number | NGC312032EC |
| Weight | 32.00 lbs (14.51 kg) |
| UPC | 786685574424 |
| Rated Current | 1200 A |
| Rated Voltage | 480 VAC / 600 VAC |
| Number of Poles | 3 Poles |
| Phase Type | 3 Phase |
| Trip Unit Type | Electronic Digitrip 310 RMS |
| Trip Functions | LSI (Long-time, Short-time, Instantaneous) |
| Interrupt Rating at 240 VAC | 200 kAIC |
| Interrupt Rating at 480 VAC | 100 kAIC |
| Terminal Connection | Line and Load |
| Minimum Frequency | 50 Hz |
| Maximum Frequency | 60 Hz |
Serving as a resilient solution for electrical circuit protection, the Eaton Cutler-Hammer NGC312032EC is a molded case circuit breaker well-suited to demanding applications. Rated for a substantial current of 1200 A, it operates under both 480 VAC and 600 VAC conditions across three phases.
The breaker uses a Digitrip 310 RMS type electronic trip unit, incorporating LSI trip functions, which effectively manage long-time, short-time, and instantaneous overloads. This advanced feature ensures that the device responds appropriately to various fault conditions, safeguarding the circuit it protects.
Its interrupt rating stands at 200 kAIC for 240 VAC and 100 kAIC for 480 VAC, indicating the breaker’s capacity to handle fault currents efficiently without failure. This robustness is essential for maintaining system integrity in high-demand scenarios. Terminal connections for both line and load are present, facilitating versatile installation options.
Designed to function within a frequency range of 50 to 60 Hz, the NGC312032EC is appropriate for diverse industrial environments, ensuring that it meets standard operational requirements while providing effective circuit protection.