Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
Eaton Cutler-Hammer Series G Circuit Breakers NGS308032E

Product image is representative; revision or series may vary. Contact us to request a specific version.

NGS308032E

|

The Eaton Cutler-Hammer NGS308032E molded case circuit breaker is engineered for effective current management in electrical systems. Rated for a maximum current of 800 A, it operates at voltages of 480 VAC and 600 VAC, making it suitable for various three-phase applications.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for NGS308032E

ManufacturerEaton Cutler-Hammer
Product TypeMolded Case Circuit Breaker
Product LineSeries G Circuit Breakers
Part NumberNGS308032E
Weight32.00 lbs (14.51 kg)
UPC786685379302
Rated Current800 A
Rated Voltage480 VAC / 600 VAC
Number of Poles3 Poles
Phase Type3 Phase
Interrupting Capacity (AIC) at 240 VAC85 kAIC
Interrupting Capacity (AIC) at 480 VAC50 kAIC
Interrupting Capacity (AIC) at 600 VAC25 kAIC
Trip Unit TypeElectronic Digitrip RMS 310
Terminal TypeLine and load side standard busbar
Relative Humidity5 to 95% (Non-Condensing)

The NGS308032E model from Eaton Cutler-Hammer belongs to the Series G Circuit Breakers, specifically designed as a molded case circuit breaker. It is crafted for operational reliability under demanding conditions. With a rated current capacity of 800 amperes, this breaker effectively handles loads in electrical systems with voltage ratings of up to 480 VAC and 600 VAC. The three-pole configuration allows for its application in three-phase electrical environments, thus supporting extensive industrial and commercial applications.

The interrupting capacity of this model is highly rated, allowing it to effectively manage fault conditions. It can achieve an interrupting capacity of 85 kAIC at 240 VAC, 50 kAIC at 480 VAC, and 25 kAIC at 600 VAC. Such ratings enhance the safety and performance of electrical systems by ensuring that potential fault currents are adequately interrupted.

For accurate and reliable trip settings, the breaker features an Electronic Digitrip RMS 310 trip unit. This advanced technology provides precise control over trip characteristics, allowing for specific adjustments as needed. The terminals are designed for standard busbar connections on both the line and load sides, facilitating straightforward integration into existing electrical systems.

In terms of environmental considerations, this molded case circuit breaker is capable of functioning in humidity conditions ranging from 5% to 95% (non-condensing). This ensures its effectiveness in various operational settings, contributing to overall system stability and performance.