Technical specifications for 92-01485-00

ManufacturerEaton Cutler-Hammer
CategoryPanelmates
Product LinePanelmate 92**
Part Number92-01485-00
Weight10.00 lbs (4.54 kg)
TypePanelMate plus 2000
Voltage120/230 Volts AC
Frequency50/60 Hertz
Amperage1 Amp
VA80
Interface BoardMM-PM21400C
EnclosureType 4 or Type 12
Audio PortYes
Serial PortSerial Ports 1 and 2

The Eaton 92-01485-00 PanelMate 92** operator interface terminal has a voltage range of 120 to 230 Volts AC, a frequency of 50 to 60 Hertz, a current rating of 1 Amp, and 80 Watts of power. This interface terminal has an MM-PM21400C interface board. If this PanelMate 92** interface terminal powers up in the “Recovery Mode,” it means that the Executive Firmware in the terminal is ruined, and it requires reloading. The terminal may also be locked, and in the process, it will load into the "Recovery Mode," thus preventing the users from accessing the "Offline/Serial Transfer Mode" in the normal way. If this occurs when installing the Eaton 92-01485-00 operator interface terminal, there are steps that must be followed to get the device back into the "Transfer Mode."

The procedure for resetting the Eaton 92-01485-00 operator interface terminal includes pressing down the control buttons 1 and 2 going from the top-down as the users concurrently cycle power on the electronics module, that is, they keep switching the power on and off. Keep pressing the control buttons till a blue screen displaying offline selection appears. Then the users can put the 92-01485-00 operator interface PanelMate terminal in "Transfer Mode" in order to download the Executive Firmware. If this procedure does not fix the problem, the users will need to disconnect the electronics module from the Panelmate terminal and then download the Executive Firmware. The 92-01485-00 operator interface terminal is recommended for use with NEMA Type 12 or Type 4 enclosures. It has 2 ports known as Serial Port 1 and Serial Port 2 that can be configured for RJ-11 and RJ-45 connections for RS-422, RS-232, and RS-485 communication.