IC660BPM100

Revisions: E J J1 
Description: The IC660BPM100 block is a GE Fanuc power monitor block. The IC660BPM100 block calculates the RMS values of various power characteristics and transmits them to a host device for analysis.
In Stock Ships Today
Request a quote for IC660BPM100

Description:

The IC660BPM100 block is a GE Fanuc power monitor block. The IC660BPM100 block calculates the RMS values of various power characteristics and transmits them to a host device for analysis.



top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: E J J1 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the IC660BPM100.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.5 with 8 reviews

    Technical Specifications for IC660BPM100

BrandGE Fanuc
SeriesGenius I-O
Part NumberIC660BPM100
Product TypePower monitor block
Input Voltage 125 Volts DC, 115 / 230 Volts AC inputs
Max. Distance to Host7500 feet
Standalone ModeYes
Burden per Voltage Input< 0.1 VA
Dimensions5.21 x 11 x 8.06 inches
Operating Temperature 32 to 140 degrees Fahrenheit
Storage Temperature -40 to 212 degrees Fahrenheit
BrandGE Fanuc
SeriesGenius I-O
Part NumberIC660BPM100
Product TypePower monitor block
Input Voltage 125 Volts DC, 115 / 230 Volts AC inputs
Max. Distance to Host7500 feet
Standalone ModeYes
Burden per Voltage Input< 0.1 VA
Dimensions5.21 x 11 x 8.06 inches
Operating Temperature 32 to 140 degrees Fahrenheit
Storage Temperature -40 to 212 degrees Fahrenheit
s

About IC660BPM100

The GE Fanuc Genius I-O IC660BPM100 power monitor block monitors voltage and current inputs and stores the waveform values for each type of input. From these stored values, the IC660BPM100 block calculates the root mean squared (RMS) values of the current, voltage, reactive power, active power, KWH, and power factor. The IC660BPM100 block also measures line frequency. The IC660BPM100 block then sends these calculated values to a connected computer or PLC for analysis. The IC660BPM100 block can be used with Wye-Delta configured 3-phase or single-phase systems. The block accepts current inputs from up to 3 line current transformers and a neutral current transformer, and voltage inputs from up to 3 potential transformers. The IC660BPM100 block is software configurable. The block has a rugged design and it can be installed in electrical process and distribution equipment.

 

The IC660BPM100 power monitor block can accept either 125 Volts DC or 115 to 230 Volts AC rated inputs. The block can be installed at distances of up to 7500 from its host computer. The block can also be used in stand-alone applications. The overvoltage rating for the voltage inputs is 300 Volts peak, the transient voltage rating is 300 Volts peak, and the burden per input is less than 0.1 VA. The overcurrent withstand for the current inputs is 50 Amps for 5 seconds at 10-minute intervals. The IC660BPM100 block measures 5.21 x 11 x 8.06 inches. The environmental specifications for the block include a 32 to 140 degrees Fahrenheit operating temperature range, a -40 to 212 degrees Fahrenheit storage temperature range, and a 50 to 95% relative humidity range for operation and storage. The vibration rating for the IC660BPM100 block is 1 G at 10 to 200 Hertz.

Repair Services for IC660BPM100

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your IC660BPM100. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for IC660BPM100

Please refer to the manual for more information about the IC660BPM100 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
IC660BPM100E
IC660BPM100-E, Series E, Rev E Request Quote
IC660BPM100J
IC660BPM100-J, Series J, Rev J Request Quote
IC660BPM100J1
IC660BPM100-J1, Series J1, Rev J1 Request Quote
Common misspellings:
  • 1C660BPM100
  • IC66oBPM100
  • IC6608PM100
  • IC660BPMl00
  • IC660BPM1o0
  • IC660BPM10o
  • IC660BPM100

Dimensions For IC660BPM100

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For IC660BPM100

Resolutions For IC660BPM100

Technical Specifications
BrandGE Fanuc
SeriesGenius I-O
Part NumberIC660BPM100
Product TypePower monitor block
Input Voltage 125 Volts DC, 115 / 230 Volts AC inputs
Max. Distance to Host7500 feet
Standalone ModeYes
Burden per Voltage Input< 0.1 VA
Dimensions5.21 x 11 x 8.06 inches
Operating Temperature 32 to 140 degrees Fahrenheit
Storage Temperature -40 to 212 degrees Fahrenheit
BrandGE Fanuc
SeriesGenius I-O
Part NumberIC660BPM100
Product TypePower monitor block
Input Voltage 125 Volts DC, 115 / 230 Volts AC inputs
Max. Distance to Host7500 feet
Standalone ModeYes
Burden per Voltage Input< 0.1 VA
Dimensions5.21 x 11 x 8.06 inches
Operating Temperature 32 to 140 degrees Fahrenheit
Storage Temperature -40 to 212 degrees Fahrenheit
About

The GE Fanuc Genius I-O IC660BPM100 power monitor block monitors voltage and current inputs and stores the waveform values for each type of input. From these stored values, the IC660BPM100 block calculates the root mean squared (RMS) values of the current, voltage, reactive power, active power, KWH, and power factor. The IC660BPM100 block also measures line frequency. The IC660BPM100 block then sends these calculated values to a connected computer or PLC for analysis. The IC660BPM100 block can be used with Wye-Delta configured 3-phase or single-phase systems. The block accepts current inputs from up to 3 line current transformers and a neutral current transformer, and voltage inputs from up to 3 potential transformers. The IC660BPM100 block is software configurable. The block has a rugged design and it can be installed in electrical process and distribution equipment.

 

The IC660BPM100 power monitor block can accept either 125 Volts DC or 115 to 230 Volts AC rated inputs. The block can be installed at distances of up to 7500 from its host computer. The block can also be used in stand-alone applications. The overvoltage rating for the voltage inputs is 300 Volts peak, the transient voltage rating is 300 Volts peak, and the burden per input is less than 0.1 VA. The overcurrent withstand for the current inputs is 50 Amps for 5 seconds at 10-minute intervals. The IC660BPM100 block measures 5.21 x 11 x 8.06 inches. The environmental specifications for the block include a 32 to 140 degrees Fahrenheit operating temperature range, a -40 to 212 degrees Fahrenheit storage temperature range, and a 50 to 95% relative humidity range for operation and storage. The vibration rating for the IC660BPM100 block is 1 G at 10 to 200 Hertz.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your IC660BPM100. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks Askenvelope Get Quote

Our highly skilled technicians can repair your IC660BPM100. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the IC660BPM100 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
IC660BPM100E
IC660BPM100/E, Series E, Rev E Request Quote
IC660BPM100J
IC660BPM100/J, Series J, Rev J Request Quote
IC660BPM100J1
IC660BPM100/J1, Series J1, Rev J1 Request Quote

Common misspellings:
  • IC66oBPM100
  • IC6608PM100
  • IC660BPMl00
  • IC660BPM1o0
  • IC660BPM10o
  • IC660BPM100
PDF