The IC630MDL325 is an input module from GE Fanuc Emerson's Series 90-30, designed to facilitate diverse control tasks. This module operates on a voltage rating of 115V AC/DC with the ability to handle input points effectively at an operating frequency ranging from 48 to 63 Hz.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | GE Fanuc Emerson |
|---|---|
| Product Line | Series 90-30 |
| Part Number | IC630MDL325 |
| Weight | 2.00 lbs (0.91 kg) |
| Module Type | Input Module |
| Voltage Rating | 115V AC/DC |
| Operating Frequency | 48 to 63 Hz |
| Number of Input Points | 16 |
| Current Range for AC Voltage | 7.5 to 14.1 mA |
| Current Range for DC Voltage | 2.2 to 4.2 mA |
| Number of Groups | 2 Input Groups |
| Indicators | LED Indicators |
| Off-Stage Voltage for AC Voltage | Less than 20V AC |
| Off-Stage Voltage for DC Voltage | Less than 30V DC |
| On-Stage Delay for AC Voltage | 10 to 40 ms |
| On-Stage Delay for DC Voltage | 6 to 30 ms |
| Operating Temperatures | 0 to 60°C |
| Battery Lifespan | 2 Years |
The GE Fanuc Emerson IC630MDL325 is a compact input module within the Series 90-30 lineup. Rated for both AC and DC at 115V, it supports up to 16 input points organized into two separate groups. This device operates effectively at a frequency range between 48 Hz and 63 Hz.
For AC signals, the module can handle an input current between 7.5 and 14.1 mA. In contrast, DC voltage operates within a range of 2.2 to 4.2 mA. Each channel is equipped with LED indicators to provide visual feedback on operational status. It includes off-stage voltage limits of less than 20V for AC inputs and under 30V for DC inputs, ensuring safe operation.
The device's on-stage delays vary by type, with AC voltages experiencing delays from 10 to 40 milliseconds and DC voltages ranging between 6 to 30 milliseconds. Ensuring reliable operation, the module can function in environments where temperatures range from 0 to 60 degrees Celsius. Additionally, the unit's battery is designed to last approximately two years, maintaining the module's functionality during its lifecycle.