Product image is representative; revision or series may vary. Contact us to request a specific version.
The IC610MDL179 output module from GE Fanuc Emerson's Series One provides robust control with 8 outputs. It operates within an input voltage range of 80 to 264V AC and supports frequencies between 47 and 63 Hz, allowing for adaptable use in various environments.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | GE Fanuc Emerson |
|---|---|
| Product Type | Output Module |
| Product Line | Series One |
| Part Number | IC610MDL179 |
| Weight | 2.00 lbs (0.91 kg) |
| Removable Terminal Block | Included |
| Voltage | 115/230V AC |
| Outputs | 8 Outputs |
| Operating Voltage Range | 80-264V AC |
| Frequency | 47-63 Hz |
| Maximum Current | 1 A |
| Maximum Rated Leakage Current | 1.2 mA at 230V and 60 Hz |
| ON Voltage Drop | 1.5V at 1 A |
| Smallest Recommended Load | 25 mA |
| OFF to ON Response Time | 1 ms |
| ON to OFF Response Time | 9 ms |
| Circuit Indicator Option | Logic Side |
The IC610MDL179 is a functional output module within the GE Fanuc Emerson Series One lineup. This module is designed to handle various voltage inputs, with an operating range from 80V to 264V AC. It can accommodate both 115V and 230V AC environments, making it versatile across multiple applications.
It provides 8 outputs, each capable of delivering a maximum current of 1 ampere. The module has rated leakage currents of 1.2 mA at 230V and 60 Hz, ensuring it satisfies safety standards during operation. The ON voltage drop is measured at 1.5 volts when passing 1 amp, which is important for maintaining efficient power levels in connected devices.
The response times are commendable, ensuring swift transitions between OFF and ON states; measuring an impressive 1 millisecond for activation and 9 milliseconds for deactivation. Additionally, its smallest recommended load stands at 25 mA, which helps define the minimum operational limits required for reliable function. Equipped with a removable terminal block, installation becomes straightforward while also allowing for straightforward maintenance.
For monitoring purposes, the module features a circuit indicator option on the logic side, providing immediate feedback on operational status. Weighing 7.4 ounces, this compact module integrates seamlessly into various control systems without adding unwanted bulk.