Product image is representative; revision or series may vary. Contact us to request a specific version.
The THHQB32080 circuit breaker from GE Fanuc Emerson's Spectra series is a robust molded case type designed for reliable performance. With a rated amperage of 80 Amps, this three-pole breaker is built to operate in 3-phase systems, with a voltage rating accommodating either 120/240 VAC or 208/240 VAC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | GE Fanuc Emerson |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | Spectra |
| Part Number | THHQB32080 |
| UPC | 783164118650 |
| Rated Amperage | 80 Amps |
| Pole Configuration | 3 Poles |
| Voltage Rating | 120/240 VAC or 208/240 VAC |
| Phase | 3-Phase |
| Connection Type | Bolt-On |
| Interrupting Rating (kAIC) | 22 kA at 208/240V |
| Trip Unit Type | Thermal-Magnetic |
| Trip Characteristic | Fixed, Non-Adjustable |
| Common Trip | Internal common trip bar |
| Terminal Type | Load Side Lugs |
| Acceptable Wire Size | 6 to 1/0 AWG Copper; 4 to 1/0 AWG Aluminum |
| Suitable for Reverse Feed | Yes |
The GE Fanuc Emerson THHQB32080 is a high-performance molded case circuit breaker, crafted for secure electrical management. This unit is rated at 80 Amps and configured with three poles, ideal for 3-phase systems. It provides compatibility with voltage levels of 120/240 VAC or 208/240 VAC, allowing flexibility for various applications.
The breaker is designed with a bolt-on connection type, facilitating straightforward installation. With a reliable interrupting rating of 22 kA at 208/240V, it ensures effective protection against electrical faults. The thermal-magnetic trip unit offers a set trip characteristic that is fixed and non-adjustable, maintaining consistent operation within specified tolerances.
An internal common trip bar is incorporated, ensuring simultaneous tripping of all poles under fault conditions, enhancing overall safety. The unit's terminals are load side lugs, compatible with wire sizes ranging from 6 to 1/0 AWG for copper conductors and 4 to 1/0 AWG for aluminum. Additionally, this breaker supports reverse feed, offering versatility in wiring configurations.