Technical specifications for HE693RTD665

ManufacturerHorner Electric
Product TypeIsolated RTD Input Module
Product LinePLC I/O
Part NumberHE693RTD665
Weight12.00 lbs (5.44 kg)
Number of Channels6
Supported RTD Sensor TypesPt-100 / Ni-120 / Cu-10 / Pt-1000 / TD5R
Input Impedance>1000 MΩ
A/D ConversionType 18-bit integrating
Resolution0.05 °C / 0.05 °F / 0.1 °C / 0.1 °F / 0.5 °C / 0.5 °F
Accuracy±0.3 °C
Update Rate12.5 channels/sec (RTD665 version)
Average RTD Current330 µA/isensor
Isolation (Field-to-Logic)1500 VAC
Isolation (Channel-to-Channel)5 VAC
Operating Temperature0–60 °C
Storage Temperature-40–85 °C
Humidity5–95% non-condensing

The isolated RTD input module HE693RTD665 from Horner Electric features an architecture designed for high precision. This module accommodates six channels that can interface with various RTD sensors such as Pt-100, Ni-120, Cu-10, Pt-1000, and TD5R. Its input impedance exceeds 1000 MΩ, ensuring it can maintain accurate readings in diverse applications.

Data is processed using an 18-bit integrating A/D conversion technique, delivering an impressive resolution down to 0.05 degrees Celsius. The overall accuracy for temperature measurements remains within ±0.3 degrees Celsius. The HE693RTD665 manages to refresh its readings with an update rate of 12.5 channels per second, providing continuous data flow for monitoring systems. The average current per RTD sensor is noted at 330 µA, contributing to the module's efficiency.

For safety and durability, this unit features isolation between field-to-logic at 1500 VAC and between channels at 5 VAC, ensuring that circuit integrity is maintained even in electrically noisy environments. It is operational in temperatures ranging from 0 to 60 degrees Celsius and can be safely stored in conditions from -40 to 85 degrees Celsius. Humidity levels can range from 5 to 95% without causing condensation, providing versatility in various environmental conditions.