Product image is representative; revision or series may vary. Contact us to request a specific version.
The Johnson Controls part number VS3-010-4-N1B-2 is an AC variable speed drive designed for bypass applications. Rated for 10 horsepower, this unit operates within a voltage range of 380 to 500 VAC across three phases.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Johnson Controls |
|---|---|
| Product Type | AC Variable Speed Drive (Bypass) |
| Product Line | Other |
| Part Number | VS3-010-4-N1B-2 |
| Horsepower Rating | 10 HP |
| Voltage Rating | 480 VAC, 3-phase (380-500 V input range, -15% to +10%) |
| Input Voltage Frequency | 50-60 Hz (variation to 45-66 Hz) |
| IP Rating | IP21 / NEMA Type 1 |
| Operating Temperature Range | -10°C (with no frost) to 50°C, up to 60°C with derating (with constant torque) |
| Storage Temperature Range | -40°C to 70°C |
| Humidity Range | 0% to 95% RH (Non-Condensing) |
| Installation Altitude | 1000 m |
| Current Rating | 14 A output current |
| Output Voltage Range | 0 VAC to the input voltage (0-480 VAC) |
| Output Frequency Range | 0 Hz to 400 Hz |
| Bypass Configuration | 2 contactor bypasses (with disconnect switch); style code N1B |
| Communication Protocols | BACnet/IP and MS/TP, Modbus TCP and RTU, and Johnson Controls SA bus |
The VS3-010-4-N1B-2 from Johnson Controls serves as an AC variable speed drive intended for bypass scenarios. This model is engineered with a robust 10 horsepower rating and a total weight of 63.7 lbs. It operates at a voltage level of 480 VAC with a three-phase configuration, supporting input voltages in the range of 380 to 500 VAC and allowing for a tolerance of -15% to +10%.
With an input voltage frequency of 50-60 Hz, this unit can also sustain frequencies from 45 Hz to 66 Hz if needed. Operating conditions are managed effectively, with temperatures ranging from -10°C (avoiding frost) to a maximum of 50°C, and can reach up to 60°C when operated with torque derating. When storage conditions are considered, it is rated to handle temperatures as low as -40°C and as high as 70°C, making it quite versatile. The humidity tolerance is suitable for non-condensing environments ranging from 0% to 95%.
The drive is designed for installations up to an altitude of 1000 meters and has an output voltage that matches the input, ranging from 0 VAC to 480 VAC. Its operational frequency extends from 0 Hz to 400 Hz, allowing for various speed and control applications. The bypass functionality incorporates two contactor bypasses, which include a disconnect switch and follows the style code N1B. It supports various communication protocols, including BACnet/IP, MS/TP, Modbus TCP, Modbus RTU, and the Johnson Controls SA bus, enhancing its connectivity and integration with other systems.