Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
Johnson Controls Other VS3-010-4-N1B-2

Product image is representative; revision or series may vary. Contact us to request a specific version.

VS3-010-4-N1B-2

|

The Johnson Controls part number VS3-010-4-N1B-2 is an AC variable speed drive designed for bypass applications. Rated for 10 horsepower, this unit operates within a voltage range of 380 to 500 VAC across three phases.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for VS3-010-4-N1B-2

ManufacturerJohnson Controls
Product TypeAC Variable Speed Drive (Bypass)
Product LineOther
Part NumberVS3-010-4-N1B-2
Horsepower Rating10 HP
Voltage Rating480 VAC, 3-phase (380-500 V input range, -15% to +10%)
Input Voltage Frequency50-60 Hz (variation to 45-66 Hz)
IP RatingIP21 / NEMA Type 1
Operating Temperature Range-10°C (with no frost) to 50°C, up to 60°C with derating (with constant torque)
Storage Temperature Range-40°C to 70°C
Humidity Range0% to 95% RH (Non-Condensing)
Installation Altitude1000 m
Current Rating14 A output current
Output Voltage Range0 VAC to the input voltage (0-480 VAC)
Output Frequency Range0 Hz to 400 Hz
Bypass Configuration2 contactor bypasses (with disconnect switch); style code N1B
Communication ProtocolsBACnet/IP and MS/TP, Modbus TCP and RTU, and Johnson Controls SA bus

The VS3-010-4-N1B-2 from Johnson Controls serves as an AC variable speed drive intended for bypass scenarios. This model is engineered with a robust 10 horsepower rating and a total weight of 63.7 lbs. It operates at a voltage level of 480 VAC with a three-phase configuration, supporting input voltages in the range of 380 to 500 VAC and allowing for a tolerance of -15% to +10%.

With an input voltage frequency of 50-60 Hz, this unit can also sustain frequencies from 45 Hz to 66 Hz if needed. Operating conditions are managed effectively, with temperatures ranging from -10°C (avoiding frost) to a maximum of 50°C, and can reach up to 60°C when operated with torque derating. When storage conditions are considered, it is rated to handle temperatures as low as -40°C and as high as 70°C, making it quite versatile. The humidity tolerance is suitable for non-condensing environments ranging from 0% to 95%.

The drive is designed for installations up to an altitude of 1000 meters and has an output voltage that matches the input, ranging from 0 VAC to 480 VAC. Its operational frequency extends from 0 Hz to 400 Hz, allowing for various speed and control applications. The bypass functionality incorporates two contactor bypasses, which include a disconnect switch and follows the style code N1B. It supports various communication protocols, including BACnet/IP, MS/TP, Modbus TCP, Modbus RTU, and the Johnson Controls SA bus, enhancing its connectivity and integration with other systems.