The Lenze EVS9321-CKV003 serves as a servo cam profiler with a power capacity of 0.37 kW (0.5 hp). Capable of operating within an input voltage range of 320 to 440 V AC, it efficiently utilizes a frequency range of 45 to 65 Hz.
We sell industrial automation parts backed by our 2-year DO Supply Warranty.
Same-day domestic and expedited international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, and more, plus flexible payment plans.
Repair and exchange services for all existing automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
Manufacturer | Lenze |
---|---|
Series | Series 9300 |
Part Number | EVS9321-CKV003 |
Product Type | Servo cam profiler |
Power Rating | 0.37 kW (0.5 hp) |
Voltage (Input) | 320-440 V AC |
Frequency (Input) | 45-65 Hz |
DC Mains Voltage (Alternative) | 450-620 V DC |
Rated Output Current (8 kHz) | 1.5 A |
Max Output Current (8 kHz) | 2.25 A |
Standstill Current (8 kHz) | 2.3 A |
Rated Output Current (16 kHz) | 1.1 A |
Max Output Current (16 kHz) | 1.65 A |
Output Voltage (With Choke) | 94% of mains voltage |
Output Voltage (Without Choke) | Up to mains voltage |
Power Loss | 100 W |
Switching Frequency | 8 kHz, 16 kHz |
Maximum Overcurrent Duration | 1 minute |
The Lenze EVS9321-CKV003 model is a servo cam profiler designed for precision operations in automation. It has a power rating of 0.37 kW, equivalent to 0.5 horsepower. This device accepts an input voltage ranging from 320 to 440 V AC and operates across an input frequency of 45 to 65 Hz.
For applications using DC mains voltage, the EVS9321-CKV003 accommodates alternative voltage levels between 450 and 620 V. At an operating frequency of 8 kHz, it provides a rated output current of 1.5 A. When the frequency increases to 16 kHz, the rated output current lowers to 1.1 A. The maximum output current at 8 kHz is 2.25 A, while it is 1.65 A at 16 kHz. The standstill current also reaches 2.3 A at the 8 kHz setting.
Output voltage characteristics vary based on choke usage. When a choke is in place, the output is 94% of the mains voltage, whereas it can reach the full mains voltage without a choke. The power loss for this profiling unit has been determined to be 100 W. To accommodate different operational requirements, the module offers switching frequencies of both 8 kHz and 16 kHz. Additionally, the design allows for a maximum overcurrent duration of one minute, ensuring reliable performance within specified parameters.