MDS-CH-SP-15

|

The Mitsubishi MDS-CH-SP-15 is a spindle drive unit with a continuous output rating of 0.75 kW. It operates at an output voltage of 340 VAC and is supported by a 2.3 A output current.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for MDS-CH-SP-15

ManufacturerMitsubishi
Product TypeSpindle drive unit
Product LineMDS Spindle Drives
Part NumberMDS-CH-SP-15
Continuous Rated Output0.75 kW
Output Rated Voltage340 VAC
Output Rated Current2.3 A
Input Rated Voltage513 to 648 VDC
Input Rated Current2.3 A
Control Power Voltage380 to 440 VAC (50Hz) / 380 to 480 VAC (60Hz)
Control Power Frequency50 / 60 Hz
Control Power CurrentMax. 0.1 A
Control Power Rush CurrentMax. 18 A
Control Power Rush Conductivity TimeMax. 6 ms
Earth Leakage Current6 (Max. 15) mA
Control MethodSine wave PWM control method
Cooling MethodForced air cooling

The Mitsubishi MDS-CH-SP-15 spindle drive unit is designed for efficient motor control. It provides a continuous rated output of 0.75 kW and operates effectively with an output voltage of 340 VAC. The output current rating is set at 2.3 A.

Regarding input specifications, this spindle drive requires a voltage range of 513 to 648 VDC, with an input current rating of 2.3 A. Furthermore, for control power, it supports voltage ratings from 380 to 440 VAC at 50 Hz and 380 to 480 VAC at 60 Hz. The MDS-CH-SP-15 drive unit can handle a maximum control power current of 0.1 A, which can surge to 18 A during rush conditions, limited to a maximum duration of 6 milliseconds.

The MDS-CH-SP-15 drive's leakage current measures 6 mA, with a maximum threshold of 15 mA. The control method is a sine wave PWM control technique, ensuring smooth performance. For cooling, it employs a forced-air mechanism. The physical weight of the MDS-CH-SP-15 drive unit is 6.5 kg, which allows for straightforward installation in various applications.