The Mitsubishi MDS-DH2-SP-320 spindle drive system has robust specifications optimized for high-performance applications. It supports a maximum peak current of 320 amperes and an output voltage rating of 340 volts AC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Mitsubishi |
|---|---|
| Product Line | MDS Spindle Drives |
| Part Number | MDS-DH2-SP-320 |
| Weight | 50.00 lbs (22.68 kg) |
| Product Classification | Spindle drive system |
| Peak Current Capacity | 320 Amperes |
| Output Voltage Rating | 340 Volts AC |
| Output Current Rating | 103 Amperes |
| Input Voltage Range | 513 to 648 Volts DC |
| Input Current Specification | 119 Amperes |
| Control Power Input | 380-440 Volts AC (50 Hz) / 380-480 Volts AC (60 Hz) |
| Permissible Control Power Variation | Voltage: ±10%, Frequency: ±3% |
| Control Strategy | PWM using sine wave modulation |
| Braking Approach | Energy recovery braking |
| Protection Rating | IP20 overall, IP00 at terminal point |
| Cooling Approach | Active air cooling |
| Maximum Ground Leakage Current | 15 Milliamperes |
| Sound Emission Level | Less than 55 Decibels |
The Mitsubishi MDS-DH2-SP-320 is engineered as a spindle drive system for demanding industrial environments. It has a considerable peak current capacity of 320 amperes and an output voltage capability of 340 volts AC. The output current is rated at 103 amperes, making this model highly effective for various applications.
It operates within an input voltage range from 513 to 648 volts DC, with a specified input current of 119 amperes. Control power requires an input of 380-440 volts AC at 50 Hz or 380-480 volts AC at 60 Hz. The system allows for slight variations in control power, with voltage tolerances of ±10% and frequency tolerances of ±3%.
Control is accomplished through a pulse-width modulation strategy that utilizes sine wave modulation for increased efficiency. The device incorporates energy recovery braking, enhancing its effectiveness during operation. Its construction adheres to IP20 overall protection and IP00 at the terminal point, helping to safeguard internal components.
Active air cooling is employed to maintain optimal operating conditions. Additionally, the system has a maximum ground leakage current rating of 15 milliamperes, ensuring user safety. The sound emission level is kept below 55 decibels when in operation, contributing to a quieter working environment.