The Omron 3G2A5-ID215 is an input unit designed for effective monitoring and control applications. With a total of 32 input points organized as 8 points per common across 4 circuits, this device supports a variety of input configurations. It operates within a voltage range of 12 to 24 VDC and has a maximum internal current consumption of 160 mA at 5 VDC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Omron |
|---|---|
| Product Type | Input Unit |
| Product Line | 3G2 |
| Part Number | 3G2A5-ID215 |
| Weight | 0.50 lbs (0.23 kg) |
| Number of Points | 32 (8 points per common, 4 circuits) |
| Internal Current Consumption | 160 mA, 5 VDC max. |
| Unit Voltage Type | DC |
| Input Voltage | 12 to 24 VDC |
| Input Impedance | 2.2 kΩ |
| Input Current | 16 mA typical (at 12 VDC) |
| ON Voltage | 10.2 VDC min. |
| OFF Voltage | 3.0 VDC max. |
| ON Response Time | 1.5 ms max. |
| OFF Response Time | 1.5 ms max. |
The 3G2A5-ID215 model from Omron falls within its 3G2 series, denoting an input unit built for robust performance in automation applications. This device comprises 32 input points, divided into 8 points per common across 4 circuits, allowing significant flexibility for system integration. It accepts a DC input voltage range of 12 to 24 VDC and maintains an internal current consumption of a maximum of 160 mA at 5 VDC.
Weighing 0.45 kg, the unit features a B-shaped structure, harmonizing compactness with functional access. The input impedance is rated at 2.2 kΩ, making it suitable for direct connection to standard industrial devices. Under normal conditions, the input current recorded is approximately 16 mA at 12 VDC. For reliable operation, the ON voltage must meet a minimum threshold of 10.2 VDC, while the OFF stage should not exceed 3.0 VDC.