| Manufacturer | Omron |
|---|---|
| Product Type | Triac Output Unit |
| Product Line | 3G2 |
| Part Number | 3G2A5-OA121 |
| Weight | 1.06 lbs (0.48 kg) |
| Maximum Switching Capacity | 1 A at 132 VAC, 50/60 Hz (4 A/common, 5 A/unit) |
| Minimum Switching Capacity | 10 mA (resistive load); 40 mA (inductive load); 10 VAC |
| Leakage Current | 3 mA max. (at 100 VAC) |
| Residual Voltage | 1.2 V max. |
| ON Response Time | 1 ms max. |
| OFF Response Time | 1/2 of load frequency max. |
| Number of Output Points | 16 (8 points/common, 2 circuits) |
| Internal Current Consumption | 300 mA at 5 VDC max. |
| Fuse Capacity | 5 A at 250 V (two fuses) |
| Circuit Configuration | Dual circuit, 8 outputs per common |
| Connection Type | Terminal block |
| Voltage Range | Up to 132 VAC |
The 3G2A5-OA121 from Omron is a Triac Output Unit engineered for advanced control applications. This component can handle a maximum switching capacity of 1 A at 132 VAC, operational in both 50 and 60 Hz environments. Notably, it facilitates loads with an impressive carrying capacity of 4 A per common and reaches a total of 5 A per unit. To ensure optimal performance, the minimum switching requirements include 10 mA for resistive loads and 40 mA for inductive loads along with a minimum voltage of 10 VAC.
When evaluating safety features, this unit exhibits a maximum leakage current of only 3 mA at 100 VAC. It delivers a residual voltage of 1.2 V at its peak. The ON response time is capped at 1 millisecond, ensuring minimal delay for initiating control commands. Furthermore, the OFF response time is conditioned to half the frequency of the load, allowing for effective operation across various voltage cycles.
This Triac output unit accommodates 16 output points organized into dual circuits, which provides 8 outputs per common. For reliable performance, the internal current consumption does not exceed 300 mA at the 5 VDC level. Two fuses rated at 5 A and 250 V are included to meet safety requirements. With a compact weight not exceeding 500 grams, this unit is designed for easy integration.
Connectivity is straightforward via a terminal block, and the unit supports voltage inputs of up to 132 VAC. Overall, the Omron 3G2A5-OA121 output unit is a compact, efficient solution for numerous applications requiring robust TRIAC output performance.