The Omron 3G2A5-OA222 serves as a Triac Output Unit designed for controlling electrical loads. With a maximum switching capability of 1 A at 250 VAC, it effectively manages dual independent circuits, providing reliable operation across various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Omron |
|---|---|
| Product Type | Triac Output Unit |
| Product Line | 3G2 |
| Part Number | 3G2A5-OA222 |
| Weight | 0.94 lbs (0.43 kg) |
| Max Switching Capacity | 1 A at 250 VAC (4 A/common, 5 A/unit) |
| Min Switching Capacity | 10 mA resistive, 40 mA inductive, 10 VAC |
| Leakage Current | 3 mA at 100 VAC, 6 mA at 200 VAC |
| Circuit Design | Dual independent circuits |
| Connections | Terminal block |
| Voltage Range | Up to 250 VAC |
| Residual Voltage | 1.2 V max. |
| ON Response Time | 1 ms max. |
| OFF Response Time | Half load frequency |
| Output Points | 16 (8/common, 2 circuits) |
| Internal Consumption | 300 mA at 5 VDC max. |
| Fuse Capacity | 5 A at 250 V |
Omron's 3G2A5-OA222, a Triac Output Unit, is engineered for effective control within electrical systems. This unit can accommodate switching loads with a maximum capacity of 1 A at a voltage of 250 VAC. For enhanced performance, the output is designed to handle two independent circuits, enabling versatile functionality. Users can expect a minimum switching capacity of 10 mA for resistive loads, 40 mA for inductive loads, and 10 VAC for additional flexibility.
The device boasts a compact A-style configuration and connects easily through terminal blocks to simplify installation. Weighing no more than 500 grams, it is manageable while still providing substantial features. The unit's leakage current is maintained at a low level, measuring 3 mA at 100 VAC and increasing to 6 mA at 200 VAC, promoting energy efficiency.
For operational response, the ON response time of the Triac output is capped at a maximum of 1 millisecond, ensuring prompt actuation, while the OFF response time varies with half the load frequency. The residual voltage is limited to a maximum of 1.2 V, preserving circuit integrity during operation. Power consumption for internal operations does not exceed 300 mA at 5 VDC. The unit includes 16 output points configured with 8 common outputs spread across two circuits. With a fuse capacity rated at 5 A for 250 V, this Triac Output Unit is well-equipped to handle substantial currents while maintaining safety and reliability.