The 3G2A5-OC221 from Omron is a contact output unit, designed for robust applications in automation. It offers a maximum switching capacity of 2 A at 250 VAC and can handle resistive and inductive loads with a mechanical relay lifespan reaching 50 million cycles.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 3G2A5-OC221

ManufacturerOmron
Product TypeContact Output Unit
Product Line3G2
Part Number3G2A5-OC221
Weight1.19 lbs (0.54 kg)
Maximum Switching Capacity2 A at 250 VAC (cos φ=1), 0.5 A at 250 VAC (cos φ=0.4), 2 A at 24 VDC (8 A/common, 16 A/unit)
Minimum Switching Capacity10 mA at 5 VDC
External Power Supply Voltage24 VDC ±10%
External Power Supply Current10 mA/point, 160 mA/unit
BitG6B-114P-FD-US-M (24 VDC) with socket
Relay Service Life (Electrical)300,000 operations (resistive load), 100,000 operations (inductive load)
Relay Service Life (Mechanical)50,000,000 operations
ON Response Time15 ms max
OFF Response Time15 ms max
Number of Points16 points (8 points/common, 2 circuits)
Internal Current Consumption100 mA at 5 VDC max
Circuit ConfigurationTwo circuits with replaceable relays on sockets

Omron's 3G2A5-OC221 is a contact output unit that delivers efficient control in industrial environments. The device supports a maximum switching capacity of 2 A at 250 VAC for resistive loads and 0.5 A for inductive loads while capable of 8 A per common or 16 A per unit at 24 VDC. This ensures compatibility with various sensor and actuator configurations.

With an operating voltage requirement of 24 VDC ±10%, the unit is designed to function effectively with an external power supply. It offers notable flexibility with its 10 mA switching capability at 5 VDC minimum. The unit features 16 output points arranged in two circuits, allowing for organized control and monitoring of multiple devices.

The response times for both ON and OFF operations are a maximum of 15 milliseconds, providing quick actuation necessary in dynamic environments. The internal current draw is capped at 100 mA at 5 VDC, ensuring efficient usage of power resources.

The lifetime of the electrical relay service is rated at 300,000 operations under resistive loads, while it withstands 100,000 operations for inductive loads. However, the mechanical relay promises even higher durability, rated at 50 million operations. The contact output unit uses the G6B-114P-FD-US-M (24 VDC) relay and has a weight of no more than 450 grams. The design incorporates replaceable relays on sockets, enhancing maintenance and adaptability.