The Omron CJ1W-ID201 CJ series input module is an 8-channel DC input module. It supports a removable terminal block for external connections. The CJ1W-ID201 input module’s rated input voltage is 12 to 24 Volts DC, and its input voltage range is from 10.2 to 26.4 Volts DC. This module supports an input impedance rating of 2.4 kiloohms. The typical input current rating is 10 milliamps at a voltage rating of 24 Volts DC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Omron |
|---|---|
| Product Line | CJ1 |
| Part Number | CJ1W-ID201 |
| Weight | 2.00 lbs (0.91 kg) |
| Series | CJ Series |
| Internal current consumption | 80 milliamps |
| Number of input points | 8 inputs |
| Rated input voltage | 12 to 24 Volts DC |
| Rated input voltage range | 10.2 to 26.4 Volts DC |
| Insulation resistance | 20 Megaohms minimum between external terminals and the GR terminal at 100V DC |
| Dielectric strenght | 1000V AC between the external terminals and the GR terminal for 1 minute at 10 mA of maximum leakage current |
| Input impedance | 2.4 kiloohms |
| ON response time | 8 milliseconds |
| OFF response time | 8 milliseconds |
The CJ1W-ID201 module is an Omron CJ series DC input module. It weighs approximately 110 grams. The internal current consumption rating of the CJ1W-ID201 DC input module is 80 milliamps maximum. This module’s dielectric strength rating is 1000 Volts AC between the external terminals and the GR terminal for a time period of 1 minute when the leakage current rating is 10 milliamps. The insulation resistance rating of the CJ1W-ID201 module is 20 Megahoms between the external terminals and the GR terminal at 100 Volts DC. All of the input points on the CJ1W-ID201 module can be in the ON state simultaneously. For every input channel, the default maximum response time required to change from the OFF state to the ON state is configurable and can be set to values ranging from 0 to 32 milliseconds. The default value is 8 milliseconds. Additionally, the default maximum response time required to change the inputs from the ON state to the OFF state is configurable and can be set to values ranging from 0 to 32 milliseconds. The default value is 8 milliseconds. The minimum voltage value required to change from the OFF state to the ON state is 8.8 Volts DC, and the minimum input current value required to change to the ON state is 3 milliamps. Additionally, the CJ1W-ID201 module’s OFF voltage rating is 3 Volts DC maximum, and its OFF current rating is 1 mA maximum. The voltage rating of the inputs is 12 Volts DC to 24 Volts DC. The input voltage range is from 10.2 to 26.4 Volts DC.