Product image is representative; revision or series may vary. Contact us to request a specific version.
The CJ1W-OD232Q output module by Omron is designed for efficient signal output control. It supports a rated voltage of 24 Volts DC, operating effectively within a load voltage range of 20.4 to 26.4 Volts DC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Omron |
|---|---|
| Product Line | CJ1 |
| Part Number | CJ1W-OD232Q |
| Weight | 3.00 lbs (1.36 kg) |
| Product | Output Module |
| Rated Voltage | 24 Volts DC |
| Load Voltage Range | 20.4 to 26.4 Volts DC |
| Maximum ON Response Time | 0.5 ms |
| Number of Digital Outputs | 32 Outputs |
| Maximum Leakage Current | 0.1 mA |
| Maximum Load Current | 0.5 Amperes per Point (4 Amperes per Unit) |
| Mounting Method | DIN Track |
| Terminal Type | Clamp Type |
| Insulation Resistance | 20 mega-ohms |
| Maximum Internal Current Consumption | 0.15 Amperes at 5 Volts DC |
| Maximum OFF Response Time | 1 ms |
| Maximum Residual Voltage | 1.5 Volts |
| Detection Current Range for Load Short-Circuit Protection | 0.7 to 2.5 Amperes |
Omron's CJ1W-OD232Q module serves as a reliable output control solution. Weighing approximately 0.17 pounds (0.08 kilograms), this compact unit operates at a rated voltage of 24 Volts DC and can handle a load voltage range between 20.4 to 26.4 Volts DC. It houses 32 digital outputs, each capable of supporting a maximum load current of 0.5 amperes. This capability allows for efficient actuation of various devices in an automated system.
The module is designed for quick signaling. It achieves a maximum ON response time of just 0.5 ms, while the maximum OFF response time is 1 ms. This fast response enhances the overall performance of control processes. Furthermore, the maximum leakage current is kept under 0.1 mA, contributing to the system's efficiency.
For safety, the CJ1W-OD232Q is equipped with load short-circuit protection. It detects current in the range of 0.7 to 2.5 amperes, ensuring that any overload situations are managed promptly. The module has an impressive insulation resistance rating of 20 mega-ohms, which helps prevent failures due to unwanted currents. It operates with a maximum internal current consumption of 0.15 amperes at 5 Volts DC.
Mounting is straightforward, as the module is compatible with DIN tracks. It utilizes clamp-type terminals for secure connections, maintaining a solid interface in control panels. The maximum residual voltage across the outputs is limited to 1.5 Volts, rounding out its specifications for robust performance in various applications.