The 8502SDO1V02S contactor from Schneider Electric is engineered for single-phase applications. Designed with a current rating of 45 A, this unit operates at a maximum voltage of 600 V AC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Contactor |
| Product Line | 8502S |
| Part Number | 8502SDO1V02S |
| UPC | 785901774037 |
| Weight | 6.00 lbs (2.72 kg) |
| Contact Configuration | 2-pole, non-reversing |
| Current Rating | 45 A |
| Max. Voltage | 600 V AC |
| Phase | Single-phase |
| Coil Supply | 110 V AC 50 Hz / 120 V AC 60 Hz |
| HP Capacity | 7.5 HP @ 230 V AC; 3 HP @ 115 V AC |
| Short-Circuit Rating | 100 kA |
| Control Circuit | Independent control circuit |
| Auxiliary Contacts | None |
| Pilot Indicator | Not fitted |
| Overcurrent Protection | Fuse not included |
| Terminal Style | Screw-clamp |
| Enclosure Rating | Open device |
The 8502SDO1V02S from Schneider Electric is a specific contactor developed for efficient control in electrical circuits. This 2-pole contactor is non-reversing and rated for a maximum current of 45 A, functioning effectively with single-phase electrical systems.
Operating at voltages up to 600 V AC, the contactor has been designed to handle demanding tasks. The coil supply voltage options include 110 V AC at 50 Hz and 120 V AC at 60 Hz, providing versatility in various setups. When it comes to horsepower capacity, this model supports up to 7.5 HP at 230 V AC, as well as 3 HP at 115 V AC.
The contactor is equipped with a short-circuit rating of 100 kA, ensuring robust performance and safety. It relies on an independent control circuit to manage its operation, although it does not include auxiliary contacts or a pilot indicator. Importantly, there is no overcurrent protection provided, such as a fuse, which should be considered during installation.
This device uses screw-clamp terminals for secure connectivity. The compact size, with dimensions of 130.3 mm in height, 109.5 mm in width, and 125.5 mm in depth, allows for easy installation in various environments. The open device enclosure rating means this contactor is not enclosed, which is suitable for many applications requiring direct exposure.