Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric Accessories NQ454L2

Product image is representative; revision or series may vary. Contact us to request a specific version.

NQ454L2

|

The Schneider Electric NQ454L2 serves as a panelboard interior featuring main lugs and designed for robust electrical distribution. It supports a rated current of 225A, suitable for three-phase systems with a voltage rating of 240V AC and 48V DC.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for NQ454L2

ManufacturerSchneider Electric
Product LineAccessories
Part NumberNQ454L2
UPC785901830665
Weight19.00 lbs (8.62 kg)
Product DescriptionPanelboard interior
Panelboard TypeMain lugs
Rated Current225 A
Busbar MaterialAluminum
Number of Spaces54 pole spaces
Voltage Phases3-phase
Wiring Configuration4-wire
Voltage Rating240 V AC / 48 V DC
Compatible Circuit Breaker TypesQOB, QOB-VH, QHB
Enclosure Nominal Height38 inches (965.2 mm)
Enclosure Nominal Width20 inches (508 mm)
Enclosure Nominal Depth5.75 inches (146.05 mm) for NEMA 1; 6.5 inches (165.1 mm) for NEMA 3R/5/12
Line Rated Current225 A
Rated Interrupted Current10 kA, 22 kA, or 65 kA
Terminal ConnectionsLug line and lug neutral (AWG 6 to 350 kcmil aluminum)

Model NQ454L2 is a panelboard interior designed by Schneider Electric, primarily featuring main lugs. Constructed to handle a substantial rated current of 225A, it is intended for 3-phase electrical systems. The voltage rating encompasses both 240V AC and 48V DC, allowing for versatile applications in different environments.

This panelboard boasts a total of 54 pole spaces, maximizing distribution capabilities. The internal busbar material consists of aluminum, which promotes efficient conductivity and reduces potential overheating issues. Its wiring configuration incorporates a 4-wire setup, which is essential for balanced current distribution across the phases.

Compatibility with a variety of circuit breaker types—namely QOB, QOB-VH, and QHB—enhances its adaptability. The enclosure dimensions measure 38 inches in height and 20 inches in width. For NEMA 1 configurations, the enclosure depth is 5.75 inches, while NEMA 3R, 5, and 12 configurations require a 6.5-inch depth, allowing for usage in different environmental conditions.

Rated interrupted current levels for the NQ454L2 model can reach up to 10 kA, 22 kA, or 65 kA based on requirements. The terminal connections are made via lugs for line and neutral, accommodating wire sizes ranging from AWG 6 to 350 kcmil in aluminum. This design ensures reliable and effective electrical distribution for various applications.