Product image is representative; revision or series may vary. Contact us to request a specific version.
The Schneider Electric NQ454L2 serves as a panelboard interior featuring main lugs and designed for robust electrical distribution. It supports a rated current of 225A, suitable for three-phase systems with a voltage rating of 240V AC and 48V DC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Line | Accessories |
| Part Number | NQ454L2 |
| UPC | 785901830665 |
| Weight | 19.00 lbs (8.62 kg) |
| Product Description | Panelboard interior |
| Panelboard Type | Main lugs |
| Rated Current | 225 A |
| Busbar Material | Aluminum |
| Number of Spaces | 54 pole spaces |
| Voltage Phases | 3-phase |
| Wiring Configuration | 4-wire |
| Voltage Rating | 240 V AC / 48 V DC |
| Compatible Circuit Breaker Types | QOB, QOB-VH, QHB |
| Enclosure Nominal Height | 38 inches (965.2 mm) |
| Enclosure Nominal Width | 20 inches (508 mm) |
| Enclosure Nominal Depth | 5.75 inches (146.05 mm) for NEMA 1; 6.5 inches (165.1 mm) for NEMA 3R/5/12 |
| Line Rated Current | 225 A |
| Rated Interrupted Current | 10 kA, 22 kA, or 65 kA |
| Terminal Connections | Lug line and lug neutral (AWG 6 to 350 kcmil aluminum) |
Model NQ454L2 is a panelboard interior designed by Schneider Electric, primarily featuring main lugs. Constructed to handle a substantial rated current of 225A, it is intended for 3-phase electrical systems. The voltage rating encompasses both 240V AC and 48V DC, allowing for versatile applications in different environments.
This panelboard boasts a total of 54 pole spaces, maximizing distribution capabilities. The internal busbar material consists of aluminum, which promotes efficient conductivity and reduces potential overheating issues. Its wiring configuration incorporates a 4-wire setup, which is essential for balanced current distribution across the phases.
Compatibility with a variety of circuit breaker types—namely QOB, QOB-VH, and QHB—enhances its adaptability. The enclosure dimensions measure 38 inches in height and 20 inches in width. For NEMA 1 configurations, the enclosure depth is 5.75 inches, while NEMA 3R, 5, and 12 configurations require a 6.5-inch depth, allowing for usage in different environmental conditions.
Rated interrupted current levels for the NQ454L2 model can reach up to 10 kA, 22 kA, or 65 kA based on requirements. The terminal connections are made via lugs for line and neutral, accommodating wire sizes ranging from AWG 6 to 350 kcmil in aluminum. This design ensures reliable and effective electrical distribution for various applications.