The Schneider Electric FAL34015 circuit breaker from the FA Series features a thermal magnetic trip unit. Designed for applications requiring a line rated current of 15 Amps, this unit accommodates three poles and includes an impressive breaking capacity with a code of A.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for FAL34015

ManufacturerSchneider Electric
Product TypeCircuit Breaker
Product LineFA Series
Part NumberFAL34015
UPC785901423201
Weight4.06 lbs (1.84 kg)
Trip Unit TechnologyThermal Magnetic
Line Rated Current15 A
Number of Poles3
Breaking Capacity CodeA
Mounting ModeUnit Mount
Magnetic Hold Current275 A
Magnetic Tripping Current600 A
Electrical ConnectionLugs (Load)
Phase ConnectionABC
Height6.4 inches
Width4.5 inches
Depth4.13 inches
Standards ComplianceUL Listed

The FAL34015 circuit breaker from Schneider Electric's FA Series is specifically designed for effective overcurrent protection. This unit incorporates thermal magnetic trip technology, providing reliable tripping action under both normal and fault conditions. With a rated current of 15 Amps, it delivers performance across three poles. The breaker has a notable breaking capacity code of A, which signifies its ability to interrupt fault currents safely.

Designed for unit mounting, the circuit breaker has a compact form factor. Its physical dimensions include a height of 6.4 inches, a width of 4.5 inches, and a depth of 4.13 inches, making it suitable for various installation scenarios. The electrical connections utilize load lugs, facilitating easy integration into existing systems. The phase configuration is designated as ABC, enabling flexible usage across trip and phase configurations.

Current ratings include a magnetic hold current of 275 A, with a higher magnetic tripping current of 600 A, ensuring that the circuit breaker activates under fault conditions to protect connected equipment. Furthermore, the FAL34015 is UL listed, confirming adherence to established safety standards for electrical components.