Product image is representative; revision or series may vary. Contact us to request a specific version.
The FAP36015MT is a circuit breaker from Schneider Electric's FA Series designed for reliable electrical protection. This device is equipped with thermal magnetic trip unit technology and is rated for a current of 15 A across three poles, making it suitable for various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | FA Series |
| Part Number | FAP36015MT |
| UPC | 785901727262 |
| Weight | 5.00 lbs (2.27 kg) |
| Trip Unit Technology | Thermal Magnetic |
| Line Rated Current | 15 A |
| Number of Poles | 3 |
| Breaking Capacity Code | A |
| Mounting Mode | Unit Mount |
| Magnetic Hold Current | 275 A |
| Magnetic Tripping Current | 600 A |
| Electrical Connection | Lugs |
| Phase Connection | ABC |
| Height | 6.4 inches |
| Width | 4.5 inches |
| Depth | 4.13 inches |
| Standards Compliance | UL Listed |
Part number FAP36015MT from Schneider Electric belongs to the FA Series and serves as a robust circuit breaker. This breaker incorporates thermal magnetic trip unit technology, which allows it to respond effectively to both overloads and short-circuits. Rated for a line current of 15 A, the FAP36015MT operates with three poles, facilitating a balanced load across different phases.
The design ensures a breaking capacity code classified as A, indicating its reliability in interrupting fault currents under specified conditions. It is mounted using the unit mount method, offering straightforward installation. The breaker holds a magnetic current of 275 A, ensuring stability during normal operation before tripping at a maximum of 600 A, thus safeguarding circuits in critical scenarios.
Electrical connections are made via lugs, promoting secure attachment within the system. The phase connections are configured as ABC, allowing for flexible application in diverse setups. Dimensions of this breaker are as follows: a height of 6.4 inches, a width of 4.5 inches, and a depth of 4.13 inches, making it compact enough for various panel configurations. This circuit breaker complies with UL standards, guaranteeing safety and reliability in its operational environment.