Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric Modicon 984 AS-S908-023

Product image is representative; revision or series may vary. Contact us to request a specific version.

AS-S908-023

|

The AS-S908-023 from Schneider Electric's Modicon 984 series serves as a reliable remote I/O processor. Featuring a dual channel design, it accommodates various network setups and allows for up to 62 remote drops across its channels.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for AS-S908-023

ManufacturerSchneider Electric
Product TypeRemote I/O Processor
Product LineModicon 984
Part NumberAS-S908-023
Weight3.25 lbs (1.47 kg)
Channel TypeDual Channel
Network TypeRemote I/O
Max Remote Drops62 (31 per channel)
Operating Temperature0°C to 60°C
Mounting TypeRack-mounted
Relative Humidity5% to 95% (non-condensing)
Max Distance10,000 ft (3,048 m)
Storage Temperature-40°C to 85°C
Power Supply Voltage5 VDC
Backplane Current350 mA
Power Consumption1.6 W
Diagnostic LEDsYes

The Schneider Electric AS-S908-023, identified as a remote I/O processor within the Modicon 984 series, is engineered for effective use in automation systems. Designed with dual channels, it supports a maximum of 62 remote drops, allowing 31 drops per channel. This versatility in network configuration caters to various application needs. The device performs reliably under an operating temperature range from 0°C to 60°C, while it can withstand even harsher conditions during storage, ranging from -40°C to 85°C.

For installation convenience, it is rack-mounted, facilitating integration into existing setups. The processor supports a notable communication distance of up to 10,000 feet (3,048 meters), making it suitable for extensive installations. In terms of environmental tolerance, it functions optimally in conditions with relative humidity from 5% to 95% without condensation.

The power requirements include a supply voltage of 5 VDC, drawing a backplane current of 350 mA with a power consumption of just 1.6 W. This ensures efficient energy usage within the system while maintaining high performance. Additionally, the presence of diagnostic LEDs aids in monitoring the operational status of the module, providing useful feedback for troubleshooting and maintenance.