Product image is representative; revision or series may vary. Contact us to request a specific version.
The Schneider Electric 140CRA21120 is a DIO drop interface featuring two redundant ports. With a rated supply voltage of 24 V DC, this interface operates efficiently between 20 to 30 V and handles a maximum supply current of 1.6 A.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Line | Modicon |
| Part Number | 140CRA21120 |
| EAN | 3595861136694 |
| Weight | 1.31 lbs (0.60 kg) |
| Product | DIO Drop Interface |
| Number of Ports | 2 redundant |
| Rated Supply Voltage | 24 V DC |
| Supply Voltage Limit | 20 to 30 V |
| Maximum Supply Current | 1.6 A at 24 V |
| Inrush Current | 30 A at 24 V |
| Maximum Buffer Time | 1 ms |
| Associated Fuse Rating | 2.5 A |
| Output Voltage | 5.1 V |
| Nominal Output Current | 3A |
| Minimum Load Current | 0A |
| Short-Circuit Protection | Yes |
| Output Overvoltage Protection | Yes |
| Power Dissipation | 11 W |
| Connection | Terminal Block-7 Poles |
The 140CRA21120 model from Schneider Electric is specifically designed as a DIO drop interface. This component incorporates two redundant ports to ensure reliable data transmission. It has a rated supply voltage set at 24 V DC, allowing for operation within a range of 20 to 30 V DC. With a maximum supply current capacity of 1.6 A, the interface can accommodate demanding requirements.
Inrush current capability is significant at 30 A when supplied at 24 V, providing ample power to overcome load fluctuations. Additionally, the output voltage is measured at 5.1 V, with a nominal output current rating of 3 A, ensuring effective handling of connected devices. Its minimum load current is zero, allowing versatility in different applications.
Safety features are integrated into the design, including both short-circuit protection and output overvoltage protection to mitigate potential risks during operation. The device is rated for a buffer time of up to 1 ms, which aids in response times for connected systems. An associated fuse rating of 2.5 A protects against overload conditions.
Power dissipation is accounted for with a rating of 11 W, sufficient for maintaining operational efficiency. Finally, the device connects through a seven-pole terminal block, allowing for straightforward wiring and connectivity.