Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric Modicon 140CRA21120

Product image is representative; revision or series may vary. Contact us to request a specific version.

140CRA21120

|

The Schneider Electric 140CRA21120 is a DIO drop interface featuring two redundant ports. With a rated supply voltage of 24 V DC, this interface operates efficiently between 20 to 30 V and handles a maximum supply current of 1.6 A.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 140CRA21120

ManufacturerSchneider Electric
Product LineModicon
Part Number140CRA21120
EAN3595861136694
Weight1.31 lbs (0.60 kg)
ProductDIO Drop Interface
Number of Ports2 redundant
Rated Supply Voltage24 V DC
Supply Voltage Limit20 to 30 V
Maximum Supply Current1.6 A at 24 V
Inrush Current30 A at 24 V
Maximum Buffer Time1 ms
Associated Fuse Rating2.5 A
Output Voltage5.1 V
Nominal Output Current3A
Minimum Load Current0A
Short-Circuit ProtectionYes
Output Overvoltage ProtectionYes
Power Dissipation11 W
ConnectionTerminal Block-7 Poles

The 140CRA21120 model from Schneider Electric is specifically designed as a DIO drop interface. This component incorporates two redundant ports to ensure reliable data transmission. It has a rated supply voltage set at 24 V DC, allowing for operation within a range of 20 to 30 V DC. With a maximum supply current capacity of 1.6 A, the interface can accommodate demanding requirements.

Inrush current capability is significant at 30 A when supplied at 24 V, providing ample power to overcome load fluctuations. Additionally, the output voltage is measured at 5.1 V, with a nominal output current rating of 3 A, ensuring effective handling of connected devices. Its minimum load current is zero, allowing versatility in different applications.

Safety features are integrated into the design, including both short-circuit protection and output overvoltage protection to mitigate potential risks during operation. The device is rated for a buffer time of up to 1 ms, which aids in response times for connected systems. An associated fuse rating of 2.5 A protects against overload conditions.

Power dissipation is accounted for with a rating of 11 W, sufficient for maintaining operational efficiency. Finally, the device connects through a seven-pole terminal block, allowing for straightforward wiring and connectivity.