Schneider Electric Other 8998SFA010XFSMA

Product image is representative; revision or series may vary. Contact us to request a specific version.

8998SFA010XFSMA

|

The Schneider Electric 8998SFA010XFSMA starter is designed for robust motor control. It operates as a full-voltage non-reversing starter with a capacity of 10 HP at 460 VAC across three phases. This model features a thermal overload relay and is suitable for environments with humidity levels up to 95% non-condensing.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 8998SFA010XFSMA

ManufacturerSchneider Electric
Product TypeStarter
Product LineOther
Part Number8998SFA010XFSMA
Start TypeFull-voltage non-reversing starter
Horsepower Rating10 HP @ 460 VAC (3-phase)
Overload RelayType melting-alloy thermal
Fuse TypeBranch fuse (Class J recommended)
Coil Voltage110–120 VAC (50/60 Hz)
Poles3-pole
Line CurrentApprox. 27 A
Interrupt Capability100 kA AIR @ 480 VAC
EnclosureMCC bucket (M6 chassis)
MountingPlug-in MCC bucket
TerminalsLug-type for power & control
Altitude LimitUp to 2000 m
Humidity95% non-condensing
Operating EnvironmentNo corrosive gases

The part number 8998SFA010XFSMA from Schneider Electric serves as a dependable starter suitable for motor control tasks requiring full voltage and non-reversing functionality. This starter is rated at 10 horsepower when operating at 460 volts AC in three-phase systems. It incorporates a melting-alloy thermal overload relay to protect motors from damage caused by excessive current. For added safety, a branch fuse, specifically Class J, is recommended.

The coil voltage specification stands between 110 and 120 VAC, catering to typical control circuit requirements. This starter is constructed with three poles and is rated for a line current of approximately 27 amperes. It also has an interrupt capability of 100 kA AIR at 480 volts AC. This characteristic ensures it can handle short-circuit conditions effectively.

Installed within an MCC bucket with the M6 chassis design, this starter is made for plug-in mounting, facilitating simple integration into existing setups. Connections are made through lug-type terminals for both power and control, ensuring secure and reliable wiring. This unit is designed to operate in environments with no corrosive gases and can function well in conditions of up to 2000 meters in altitude. Furthermore, it can handle humidity levels of up to 95% without condensation, making it versatile for various applications.