The HDL26100 circuit breaker from Schneider Electric's PowerPact series offers a dependable solution for electrical protection. Designed for a rated current of 100 A, it operates effectively across three poles.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for HDL26100

ManufacturerSchneider Electric
Product TypeCircuit Breaker
Product LinePowerPact
Part NumberHDL26100
UPC785901577942
Weight3.00 lbs (1.36 kg)
Line Rated Current100 A
Number of Poles3
Control TypeToggle
Breaking Capacity CodeD
Maximum Breaking Capacity25 kA
Rated Operational Voltage690 VAC
Minimum Operating Frequency50 Hz
Maximum Operating Frequency60 Hz
Rated Impulse Withstand Voltage8 kV
Trip Unit TechnologyThermal Magnetic
Magnetic Tripping Current1700 A
Magnetic Hold Current900 A
Continuous Current Rating80%

The HDL26100 model from Schneider Electric represents the PowerPact series of circuit breakers. This device is designed with precision to handle a line rated current of 100 amperes and features three poles for robust circuit protection. Functionality is enhanced by a toggle control mechanism which simplifies operation.

The circuit breaker is rated at a maximum breaking capacity of 25 kA, ensuring it can interrupt substantial fault currents safely. It operates efficiently under a rated operational voltage of 690 VAC and is compatible with minimum and maximum operating frequencies of 50 Hz and 60 Hz, respectively. The HDL26100 has a rated impulse withstand voltage of 8 kV, making it suitable for environments where high voltage transients may occur.

Utilizing thermal magnetic trip technology, this breaker provides reliable performance under varied conditions. The magnetic tripping occurs at a threshold of 1700 A, while it holds at a constant magnetic hold current of up to 900 A. The continuous current rating is specified at 80% of its line rated capacity, which allows for safe operation within normal ranges. Weighing in at 2.2 kg, the HDL26100 is compact yet designed for sturdiness and reliability in electrical systems.