Product image is representative; revision or series may vary. Contact us to request a specific version.
The HLA36110, produced by Schneider Electric, is a circuit breaker with significant capabilities. Featuring a line rated current of 110 Amperes, it effectively manages electrical loads and circuits.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | PowerPact |
| Part Number | HLA36110 |
| UPC | 785901507192 |
| Weight | 4.00 lbs (1.81 kg) |
| Number of Poles | 3 Poles |
| Line Rated Current | 110 Amperes |
| Magnetic Hold Current | 900 Amperes |
| Magnetic Tripping Current | 1,700 Amperes |
| Breaking Capacity | 20 kA at 250 Volts DC; 50 kA at 500 Volts DC; 125 kA at 240 Volts AC; 100 kA at 480 Volts AC; 50 kA at 600 Volts AC |
| Rated Operating Voltage | 690 Volts AC |
| Electrical Connection Type | I-Line connection, lugs line, and lugs load |
| Mounting Method | I-Line bracket |
| Mounting Height | 4.3 inches (114.3 millimeters) |
| Ambient Operating Temperature | -25 to 70°C (in a non-condensing environment) |
| Storage Temperature | -50 to 85°C (in a non-condensing environment) |
| Local Signalling | 1 green LED indicator |
| Communication Interface | Ethernet and Modbus |
Schneider Electric’s HLA36110 circuit breaker is designed for robust performance in complex electrical systems. This model operates with a rated current of 110 Amperes and features a magnetic hold current of 900 Amperes, ensuring reliability in high-demand situations. The magnetic tripping current is rated at 1,700 Amperes, contributing to effective electrical safety.
With three poles, the HLA36110 supports a wide range of breaking capacities: 20 kA at 250 Volts DC, 50 kA at 500 Volts DC, and 125 kA at 240 Volts AC. It can also handle 100 kA at 480 Volts AC and 50 kA at 600 Volts AC, all while maintaining a rated operating voltage of 690 Volts AC.
For connections, this circuit breaker uses an I-Line connection design along with line lugs and load lugs, facilitating easy integration into existing systems. It mounts securely with an I-Line bracket at a height of 4.3 inches (114.3 millimeters).
Operating conditions for the HLA36110 are specified for temperatures ranging from -25 to 70°C in environments without moisture. For storage, it can withstand temperatures between -50 to 85°C without compromising performance. It includes a local signaling feature with a green LED indicator for operational status, enhancing visibility. Additionally, it supports communication protocols via Ethernet and Modbus to ensure compatibility with modern control systems. This circuit breaker weighs 4.9 pounds (2.2 kilograms) and is engineered for reliable performance and flexibility in various application scenarios.