MGA268002

|

The MGA268002 by Schneider Electric is a robust molded-case circuit breaker designed for high-performance applications. This 2-pole unit provides up to 800 amperes of rated current.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for MGA268002

ManufacturerSchneider Electric
Product TypeMolded-case breaker
Product LinePowerPact
Part NumberMGA268002
UPC785901420293
Weight28.00 lbs (12.70 kg)
Pole Configuration2-pole
Rated Current800 A
Voltage Rating600 VAC, 50/60 Hz
Interrupt Capacity @ 240 V65 kA
Interrupt Capacity @ 480 V35 kA
Interrupt Capacity @ 600 V18 kA
Service-break Capacity (Ics)25 kA @ 240 V; 20 kA @ 380/415 V
Insulation Voltage (Ui)750 V
Impulse Withstand Voltage (Uimp)8 kV
Trip UnitET 1.0 electronic
Adjustable Trip Range300–800 A
Magnetic Pickup Range1,600–8,000 A
Continuous-duty Rating80 %
MountingI-Line bus-bar

The Schneider Electric MGA268002 is a molded-case circuit breaker that provides reliable protection in electrical systems. It features a 2-pole configuration and is capable of handling a rated current of 800 A. This unit is designed for operation at a voltage of 600 VAC and supports both 50 and 60 Hz frequency applications.

The interrupt capacities are noteworthy: at 240 V, the unit can handle 65 kA; at 480 V, it is rated at 35 kA; and at 600 V, it has an interrupt capacity of 18 kA. Additionally, the service-break capacity (Ics) is rated at 25 kA for 240 V and 20 kA for 380/415 V, demonstrating its strong performance in fault conditions.

In terms of insulation specifications, the insulation voltage (Ui) reaches 750 V, while the impulse withstand voltage (Uimp) is rated at 8 kV. An ET 1.0 electronic trip unit controls the operation, allowing an adjustable trip range from 300 A to 800 A, accommodating various load requirements. For higher loads, the magnetic pickup range spans from 1,600 to 8,000 A.

The circuit breaker is built for continuous-duty operation up to 80%. It is designed for mounting on an I-Line bus-bar, making it suitable for integration in larger electrical systems. Overall, the MGA268002 is engineered to provide dependable circuit protection and enhance safety in electrical installations.