The Schneider Electric MGL26600 is a molded case circuit breaker designed for robust electrical performance. With a rated current of 600 A, it features an electronic trip unit suitable for various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Molded case circuit breaker |
| Product Line | PowerPact |
| Part Number | MGL26600 |
| UPC | 785901507604 |
| Weight | 28.00 lbs (12.70 kg) |
| Rated Current | 600 A |
| Trip Unit | Electronic, basic type |
| Interrupt Rating (UL) | 65 kA @ 240V, 35 kA @ 480V, 18 kA @ 600V AC |
| Interrupt Rating (IEC) | 50 kA @ 240V, 35 kA @ 415V AC |
| Service Capacity (Ics) | 25 kA @ 240V, 20 kA @ 415V AC |
| Operational Voltage | 600V AC, 50/60 Hz |
| Insulation Voltage | 750V |
| Impulse Voltage | 8 kV |
| Magnetic Trip Range | 1.2–6 kA |
| Thermal Setting Range | 300–800 A adjustable |
| Load Capacity | 80% continuous duty |
| Conductor Range | 3x 3/0 AWG to 3x 500 kcmil Cu/Al |
| Mounting | Unit-mount with lugs |
| Size (HxWxD) | 327 × 210 × 204 mm |
The MGL26600 circuit breaker from Schneider Electric’s PowerPact series is built to manage significant electrical loads effectively. It is rated for a maximum current of 600 A and possesses an electronic trip unit that enhances operational safety. The breaker is equipped to interrupt fault currents, achieving high values of 65 kA at 240V and 35 kA at 480V, in line with UL ratings. IEC ratings showcase its endurance with 50 kA at 240V and 35 kA at 415V AC.
Service capacity ratings indicate that it can handle 25 kA at 240V and 20 kA at 415V AC, ensuring its reliability in critical applications. The device operates under a voltage of up to 600V AC across both 50 and 60 Hz frequency systems. Its insulation voltage stands at 750V, which provides an additional safety margin.
For extreme conditions, this molded case circuit breaker withstands an impulse voltage up to 8 kV. The thermal setting of the MGL26600 is adjustable between 300 and 800 A, allowing customization based on specific load requirements. The magnetic trip function is designed to operate within a range of 1.2 to 6 kA, enhancing the module's operational versatility.
This device is intended for a load capacity of 80% in continuous duty, which is appropriate for sustained operations. Its conductor range supports compatibility with sizes from 3x 3/0 AWG to 3x 500 kcmil for both copper and aluminum conductors. The unit can be securely mounted with lugs and has compact dimensions of 327 mm in height, 210 mm in width, and 204 mm in depth, making it suitable for efficient use in various settings.