Product image is representative; revision or series may vary. Contact us to request a specific version.
The QDA221002 from Schneider Electric is a robust two-pole circuit breaker designed to handle up to 100 amperes of line-rated current. It features thermal-magnetic trip unit technology, ensuring effective protection against overloads and short circuits.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | PowerPact |
| Part Number | QDA221002 |
| UPC | 785901701965 |
| Weight | 5.00 lbs (2.27 kg) |
| Line Rated Current | 100 A |
| Number of Poles | 2 |
| Control Type | Operating Handle |
| Breaking Capacity Code | D |
| Breaking Capacity | 25 kA |
| Rated Operational Voltage | 240 V |
| Minimum Operating Frequency | 50 Hz |
| Maximum Operating Frequency | 60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Trip Unit Technology | Thermal-Magnetic |
| Magnetic Tripping Current | 2400 A |
| Magnetic Hold Current | 1200 A |
| Continuous Current Rating | 80% |
| Mounting Mode | I-Line Bracket |
The QDA221002 circuit breaker belongs to Schneider Electric’s PowerPact series and is specifically engineered for reliability in electrical distribution. This device accommodates a line-rated current of 100 A and comes equipped with two poles for enhanced capacity. Its control is facilitated through an operating handle, providing straightforward operation.
The circuit breaker boasts a breaking capacity of 25 kA, offering strong protection against electrical faults. It’s designed to operate optimally at a rated voltage of 240 V and functions effectively over both minimum and maximum operating frequencies of 50 Hz and 60 Hz, respectively. With a rated impulse withstand voltage of 8 kV, this circuit breaker can endure short circuit situations without sustaining damage.
Employing thermal-magnetic trip unit technology, the QDA221002 automatically trips at a magnetic tripping current of 2400 A and maintains a magnetic hold current of 1200 A, thus ensuring safety under varying load conditions. The continuous current rating functionality is set at 80%, which adds robustness against prolonged service. For installation, the mounting is accomplished using an I-Line bracket, allowing for seamless integration into existing electrical systems.